Replacing Failing SSA Disk

From: Tim Muller (aix_sa_706@YAHOO.COM)
Date: Tue Mar 09 2004 - 11:22:02 EST


I am getting an SSA_DISK_ERR4 error on my J40 running
AIX 4.3.3. The disk is in a mirrored VG. I have
never replaced a disk on a running system before, so
I'd feel better if someone would look over the
procedure I'm planning to follow and let me know if I
am overlooking anything. Thanks very much.

unmirrorvg oravg hdisk17
reducevg oravg hdisk17
rmdev -l hdisk17 -d
[replace disk drive, let the drive be renamed hdisk17]
extendvg oravg hdisk17
mirrorvg oravg

=====
Tim Muller
Hamilton Co. Dept. of Job & Family Services
Cincinnati, OH USA

__________________________________
Do you Yahoo!?
Yahoo! Search - Find what you’re looking for faster
http://search.yahoo.com



This archive was generated by hypermail 2.1.7 : Wed Apr 09 2008 - 22:17:41 EDT