Re: ssa speed question

From: Bob.Kelley@BRINKSINC.COM
Date: Wed Jul 02 2003 - 16:15:56 EDT


This prolly doesnt help but.......I dont remember seeing errors bc of this!
I was running OEM SSA drawers which had 40mb/sec looping, and saw ZERO
errors..

Bobby Kelley
Sr. AIX/UNIX Administrator

|---------+---------------------------->
| | Bill Verzal |
| | <BVerzal@KOMATSUN|
| | A.COM> |
| | Sent by: IBM AIX |
| | Discussion List |
| | <aix-l@Princeton.|
| | EDU> |
| | |
| | |
| | 07/02/2003 02:31 |
| | PM |
| | Please respond to|
| | IBM AIX |
| | Discussion List |
| | |
|---------+---------------------------->
>------------------------------------------------------------------------------------------------------------------------------|
  | |
  | To: aix-l@Princeton.EDU |
  | cc: |
  | Subject: ssa speed question |
>------------------------------------------------------------------------------------------------------------------------------|

I've got a B80 with a SSA-160 adapter connected to (4) 7133-020 drawers.
Obviously, the SSA-160 adapter is 160Mb/s (bi-directional). The 7133-020
drawers are 40Mb/sec (bi-directional).

I'm getting errors every hour on ssa0. Would this be because it is running
at a degraded speed due to the older drawers ?

Thanks, Bill.
--------------------------------------------------------

Bill Verzal
AIX Administrator, Komatsu America
(847) 970-3726 - direct
(847) 970-4184 - fax