partial SUMMARY: SunStorage 3310 (SCSI) EMU problem

From: Grzegorz Bakalarski (G.Bakalarski@icm.edu.pl)
Date: Wed Dec 13 2006 - 07:05:45 EST


On Wed, Dec 13, 2006 at 10:23:39AM +0100, Grzegorz Bakalarski wrote:
> sccli> show enclosure-status
> Ch Id Chassis Vendor Product ID Rev Package Status
> -----------------------------------------------------------------
> 0 14 005C0A SUN StorEdge 3310 A A000 A000 Fault
>
> Enclosure Component Status:
> Type Unit Status FRU P/N FRU S/N Add'l Data
> ------------------------------------------------------------------
> Fan 0 OK 370-5398 108198 --
> Fan 1 OK 370-5398 108228 --
> PS 0 OK 370-5398 108198 --
> PS 1 OK 370-5398 108228 --
> Temp 0 OK 370-5524 005C0A temp=22
> Temp 1 OK 370-5524 005C0A temp=22
> Temp 2 OK 370-5398 108198 temp=22
> Temp 3 OK 370-5394 026348 temp=30
> Temp 4 OK 370-5394 026023 temp=23
> Temp 5 OK 370-5524 005C0A temp=22
> Temp 6 OK 370-5398 108228 temp=23
> EMU 0 Unknown 370-5394 026348
> EMU 1 Unknown 370-5394 026023
> DiskSlot 0 Absent 370-5524 005C0A addr=0,led=off
> DiskSlot 1 Absent 370-5524 005C0A addr=1,led=off
> DiskSlot 2 Absent 370-5524 005C0A addr=2,led=off
> DiskSlot 3 Absent 370-5524 005C0A addr=3,led=off
> DiskSlot 4 Absent 370-5524 005C0A addr=4,led=off
> DiskSlot 5 Absent 370-5524 005C0A addr=5,led=off
> DiskSlot 6 OK 370-5524 005C0A addr=0,led=off
> DiskSlot 7 OK 370-5524 005C0A addr=1,led=off
> DiskSlot 8 OK 370-5524 005C0A addr=2,led=off
> DiskSlot 9 OK 370-5524 005C0A addr=3,led=off
> DiskSlot 10 OK 370-5524 005C0A addr=4,led=off
> DiskSlot 11 OK 370-5524 005C0A addr=5,led=off
>
>
> Enclosure SCSI Channel Type: single-bus
> sccli>
>

Hi,

Nobody responded yet. However I have some better result now.
I'v upgreaded saf-te firmware from factory default (A00000)
to rev 1170 (patch 113722-09) and now I get the following:

sccli> show enclosure-status
Ch Id Chassis Vendor Product ID Rev Package Status
-----------------------------------------------------------------
 0 14 005C0A SUN StorEdge 3310 A 1170 1170 OK

Enclosure Component Status:
     Type Unit Status FRU P/N FRU S/N Add'l Data
------------------------------------------------------------------
      Fan 0 OK 370-5398 108198 --
      Fan 1 OK 370-5398 108228 --
       PS 0 OK 370-5398 108198 --
       PS 1 OK 370-5398 108228 --
     Temp 0 OK 370-5524 005C0A temp=21
     Temp 1 OK 370-5524 005C0A temp=21
     Temp 2 OK 370-5398 108198 temp=22
     Temp 3 OK 370-5394 026348 temp=27
     Temp 4 OK 370-5394 026023 temp=22
     Temp 5 OK 370-5524 005C0A temp=22
     Temp 6 OK 370-5398 108228 temp=23
      EMU 0 OK 370-5394 026348
      EMU 1 OK 370-5394 026023
 DiskSlot 0 Unknown 370-5524 005C0A addr=0,led=off
 DiskSlot 1 Unknown 370-5524 005C0A addr=1,led=off
 DiskSlot 2 Unknown 370-5524 005C0A addr=2,led=off
 DiskSlot 3 Unknown 370-5524 005C0A addr=3,led=off
 DiskSlot 4 Unknown 370-5524 005C0A addr=4,led=off
 DiskSlot 5 Unknown 370-5524 005C0A addr=5,led=off
 DiskSlot 6 OK 370-5524 005C0A addr=0,led=off
 DiskSlot 7 OK 370-5524 005C0A addr=1,led=off
 DiskSlot 8 OK 370-5524 005C0A addr=2,led=off
 DiskSlot 9 OK 370-5524 005C0A addr=3,led=off
 DiskSlot 10 OK 370-5524 005C0A addr=4,led=off
 DiskSlot 11 OK 370-5524 005C0A addr=5,led=off

Enclosure SCSI Channel Type: split-bus
sccli>

Note: EMU 0 and EMU 1 have OK status.
And also SCSI Channel Type is correct i.e.
split-bus.

The only concern is now why disks in slots [0-5]
are Unknown ????

Kind regards,

Gb
_______________________________________________
sunmanagers mailing list
sunmanagers@sunmanagers.org
http://www.sunmanagers.org/mailman/listinfo/sunmanagers