From: Michael Hase (michael@six.de)
Date: Wed Nov 16 2005 - 07:59:39 EST
Hi,
after a power loss a new v240 (solaris 10) can't see a previously defined
diskset on a third party scsi raid array (transtec 6200):
# metaset
Set name = trans1, Set number = 1
Host Owner
v240 No (auto)
Drive Dbase
c5t0d0 No
# metaset -s trans1 -t
metaset: v240: rpc.metad: Permission denied
# metaset -s trans1 -f -t
metaset: v240: trans1: not owner of metadevice database
# metaset -s trans1 -f -C take
metaset: v240: trans1: not owner of metadevice database
The strange thing is, it seems there are no metadb replicas on c5t0d0.
Disk slices look correct like any disk in a diskset: s7 15mb on cyl 0,
the rest of 545gb on slice 0.
There is only one host defined for this diskset, because it's still in
setup and testing. It is planned to give access to a second sun box as a
cold standby.
Is this svm diskset config messed up? Can we repair it somehow? It would
be no problem to delete the diskset if necessary, but I really would like
to be able to handle such a situation.
Local metadevices all look ok.
Thanks,
Michael
-- i.A. Michael Hase Six Offene Systeme GmbH michael@six.de Am Wallgraben 99 http://www.six.de 70565 Stuttgart phone +49 711 99091 62 Germany _______________________________________________ sunmanagers mailing list sunmanagers@sunmanagers.org http://www.sunmanagers.org/mailman/listinfo/sunmanagers