Re: Re: A1000 question

From: aalinaser@cox.net
Date: Fri Jul 01 2005 - 11:16:18 EDT


Thanks to all who responded, you are all very kind.
Now Jim's response contradicts every body else's.
The reason I asked this question was for several reason and one of thos I posted earlier on the list. On this array, I was continuously getting the following errors;

----------------------------------------------------
Jun 2 13:21:33 MySun unix: WARNING: md: d5: write error on /dev/dsk/c2t2d0s5
Jun 2 13:21:33 MySun unix: WARNING: /pci@1f,4000/scsi@4/sd@2,0 (sd32):
Jun 2 13:21:33 MySun SCSI transport failed: reason 'reset': giving up
Jun 2 13:21:33 MySun unix: WARNING: md: d6: write error on /dev/dsk/c2t2d0s7
Jun 2 13:21:33 MySun unix: WARNING: /pci@1f,4000/scsi@4/sd@2,0 (sd32):
Jun 2 13:21:33 MySun SCSI transport failed: reason 'reset': giving up
Jun 2 13:21:33 MySun unix: WARNING: md: d4: write error on /dev/dsk/c2t2d0s4
Jun 2 13:21:33 MySun unix: WARNING: /pci@1f,4000/scsi@4/sd@3,0 (sd33):
Jun 2 13:21:33 MySun SCSI transport failed: reason 'reset': giving up
Jun 2 13:21:33 MySun unix: WARNING: md: d3: write error on /dev/dsk/c2t3d0s3
Jun 2 13:21:36 MySun unix: WARNING: /pci@1f,4000/scsi@4 (glm2):
Jun 2 13:21:36 MySun Resetting scsi bus, got incorrect phase from (0,0)
Jun 2 13:21:39 MySun unix: WARNING: /pci@1f,4000/scsi@4 (glm2):
Jun 2 13:21:39 MySun Resetting scsi bus, got incorrect phase from (0,0)
----------------------------------------------

I reseated all the drives and rebooted the machine with "-r" option, ever since the above errors have disappeared, but get Soft and Hard Errors on some of the disks when run "iostat -E"

Do not know what to make out of it. All the application seem to run fine.

Thanks again to all of you.

Regards

>
> From: Jim Holland <jimholl62@yahoo.com>
> Date: 2005/07/01 Fri AM 11:00:18 EDT
> To: aalinaser@cox.net
> Subject: Re: A1000 question
>
>
>
> No ... the scsi channel auto terminates
>
>
> --- aalinaser@cox.net wrote:
>
> > Hello All,
> > This is a quick question. I have a SUN A1000
> > attached to E450. This A1000 has two PCI SCSI ports
> > on the back, one is directly connected to the Server
> > and the other is open. Does the second one has to be
> > terminated?
> >
> > Thanks
> > _______________________________________________
> > sunmanagers mailing list
> > sunmanagers@sunmanagers.org
> >
> http://www.sunmanagers.org/mailman/listinfo/sunmanagers
_______________________________________________
sunmanagers mailing list
sunmanagers@sunmanagers.org
http://www.sunmanagers.org/mailman/listinfo/sunmanagers