got scsi bus reset error in E250

From: prashant singh (prash_pcs@yahoo.com)
Date: Tue Aug 31 2004 - 09:10:37 EDT


Hi all
i am using a SUN E250 machine as a firewall long back i have upgraded this machine with 72 gb hard disk and it was working fine ,
but for the last one week it start giving error indicating for both hard disk
sample text is as follows
 
******************************************************************************************************
Aug 27 11:10:36 noidaFW scsi: [ID 365881 kern.info] /pci@1f,4000/scsi@3 (glm0):
Aug 27 11:10:36 noidaFW Cmd (0x35681a0) dump for Target 8 Lun 0:
Aug 27 11:10:36 noidaFW scsi: [ID 365881 kern.info] /pci@1f,4000/scsi@3 (glm0):
Aug 27 11:10:36 noidaFW cdb=[ 0x2a 0x0 0x8 0x7f 0x16 0x6f 0x0 0x
0 0x1 0x0 ]
Aug 27 11:10:36 noidaFW scsi: [ID 365881 kern.info] /pci@1f,4000/scsi@3 (glm0):
Aug 27 11:10:36 noidaFW pkt_flags=0x4000 pkt_statistics=0x60 pkt_state=0
x7
Aug 27 11:10:36 noidaFW scsi: [ID 365881 kern.info] /pci@1f,4000/scsi@3 (glm0):
Aug 27 11:10:36 noidaFW pkt_scbp=0x0 cmd_flags=0x1860
Aug 27 11:10:36 noidaFW scsi: [ID 107833 kern.warning] WARNING: /pci@1f,4000/scs
i@3 (glm0):
Aug 27 11:10:36 noidaFW Disconnected tagged cmd(s) (1) timeout for Targe
t 8.0
Aug 27 11:10:36 noidaFW genunix: [ID 408822 kern.info] NOTICE: glm0: fault detec
ted in device; service still available
Aug 27 11:10:36 noidaFW genunix: [ID 611667 kern.info] NOTICE: glm0: Disconnecte
d tagged cmd(s) (1) timeout for Target 8.0
Aug 27 11:10:36 noidaFW glm: [ID 401478 kern.warning] WARNING: ID[SUNWpd.glm.cmd
_timeout.6018]
Aug 27 11:10:36 noidaFW scsi: [ID 107833 kern.warning] WARNING: /pci@1f,4000/scs
Aug 27 11:10:54 noidaFW fw: [ID 209021 kern.notice] FW-1: lost 4 log/trap messag
es
Aug 27 11:10:36 noidaFW scsi: [ID 107833 kern.warning] WARNING: /pci@1f,4000/scs
i@3 (glm0):
Aug 27 11:10:36 noidaFW Disconnected tagged cmd(s) (1) timeout for Targe
t 8.0
Aug 27 11:10:36 noidaFW genunix: [ID 408822 kern.info] NOTICE: glm0: fault detec
ted in device; service still available
Aug 27 11:10:36 noidaFW genunix: [ID 611667 kern.info] NOTICE: glm0: Disconnecte
d tagged cmd(s) (1) timeout for Target 8.0
Aug 27 11:10:36 noidaFW glm: [ID 401478 kern.warning] WARNING: ID[SUNWpd.glm.cmd
_timeout.6018]
Aug 27 11:10:36 noidaFW scsi: [ID 107833 kern.warning] WARNING: /pci@1f,4000/scs
i@3 (glm0):
Aug 27 11:10:36 noidaFW got SCSI bus reset
Aug 27 11:10:36 noidaFW genunix: [ID 408822 kern.info] NOTICE: glm0: fault detec
ted in device; service still available
Aug 27 11:10:36 noidaFW genunix: [ID 611667 kern.info] NOTICE: glm0: got SCSI bu
s reset
Aug 27 11:10:36 noidaFW scsi: [ID 107833 kern.warning] WARNING: /pci@1f,4000/scs
i@3/sd@8,0 (sd7):
Aug 27 11:10:36 noidaFW SCSI transport failed: reason 'reset': retrying
command
Aug 27 11:10:36 noidaFW scsi: [ID 107833 kern.warning] WARNING: /pci@1f,4000/scs
i@3/sd@8,0 (sd7):
Aug 27 11:10:36 noidaFW SCSI transport failed: reason 'timeout': retryin
g command
Aug 27 11:10:53 noidaFW fw: [ID 773370 kern.notice] FW-1: log message queue is f
ull
Aug 27 11:10:54 noidaFW fw: [ID 209021 kern.notice] FW-1: lost 4 log/trap messag
es
****************************************************************************************************
 
 
during this time server stops responding and i loose the packets , i have disconnected the cdrom drive as it was giving error for sync slow down and removed extra hard disk which was connected to this machine and also changed the same hardisk for what error shown above ,
there no extra devices are connected with this system accept the two hard disk ,and the errors are coming for both hard disk ,in a same manner
 
IF ANY ONE CAN HELP ME OUT ON THIS I WILL BE VERY THANKFUL
 
THANKS TO ALL
PRASHANT
New and Improved Yahoo! Mail - Send 10MB messages!
_______________________________________________
sunmanagers mailing list
sunmanagers@sunmanagers.org
http://www.sunmanagers.org/mailman/listinfo/sunmanagers