Help with Sun StorEdgeA1000

From: Frode Villumstad (frode.villumstad@imap.ost.eltele.no)
Date: Tue Apr 09 2002 - 19:12:30 EDT


Hi

I have a problem with a Sun StorEdge A1000.

The problem started with two faulty disks. For some reason I booted the
server (an Enterprise 450). After the boot the relative paths for the
LUN changed. Before boot it was /dev/dsk/c4t3d0s0 and turned to
/dev/dsk/c5t3d0s0.
Now i get the message:

WARNING: The Array driver is returning an Errored I/O, with errno 5, on
Module 2
, Lun 0, sector 16

WARNING: /pci@6,4000/scsi@3/sd@3,0 (sd243):
         i/o to invalid geometry

It does not show in the format menu either.

Can someone tell me what I can do to resolve this without loosing all my
data?

Regards
Frode Villumstad

_______________________________________________
sunmanagers mailing list
sunmanagers@sunmanagers.org
http://www.sunmanagers.org/mailman/listinfo/sunmanagers