Antwort: Re: splstdata - command fails after migration from a node

From: fmu@OERAG.DE
Date: Mon Oct 27 2003 - 07:20:45 EST


Hi *!

Sorry, I have forgotten to write it. I already check this and it shows o.k.

# SDRGetObjects -G Node node_number==1
node_number hdw_enet_addr frame_number slot_number slots_used
switch_node_number switch_chip_port switch_chip switch_number
initial_hostname reliable_hostname default_route boot_server bootdisk
install_image install_disk last_install_time last_install_image
switch_protocol switch_partition_number bootp_response boot_device
usr_maint JM_domain_id VSD_adapter VSD_max_buffer_count
VSD_request_blocks VSD_pbufs VSD_init_buffer_count
VSD_min_buddy_buffer_size VSD_max_buddy_buffer_size VSD_max_buddy_buffers
cfs_adapter acct_class_id acct_enable acct_job_charge acct_excluse_enable
usr_server_ip usr_client_adapter has_usr_clients code_version
usr_gateway_ip VSD_maxIPmsgsz lppsource_name processors_installed
processor_type VSD_do_ip_checksum description platform
hardware_control_type RVSD_version selected_vg dcehostname expansion_list
on_switch primary_enabled LPAR_name
           1 02608C2D9329 1 1 2
0 -1 -1 -1 charon charon_e
100.100.1.5 0 hdisk1 helios_433_061201 hdisk0,hdisk1
Thu_Oct_23_16:17:23_DFT_2003 helios_433_061201 IP 1
disk "" false "" "" ""
"" "" "" 4096 65536
4 "" default default 1.0 false local
"" false PSSP-3.5 0 24576 aix510
1 UP false 135_MHz_P2SC_Wide rs6k 83 ""
rootvg "" "" 0 false ""

Best regards,
Frank Mueller

                      Holger.VanKoll@SW
                      ISSCOM.COM An: aix-l@Princeton.EDU
                      Gesendet von: IBM Kopie:
                      AIX Discussion Thema: Re: splstdata - command fails after migration from a node
                      List
                      <aix-l@Princeton.
                      EDU>

                      27.10.2003 12:21
                      Bitte antworten
                      an IBM AIX
                      Discussion List

splstdata is a shell-script, so invoking it with ksh -x might give more
info

or use SDRGetObjects Node to compare sdr-data of a working node with
this one

-----Original Message-----
From: fmu@OERAG.DE [mailto:fmu@OERAG.DE]
Sent: Monday, October 27, 2003 12:01 PM
To: aix-l@Princeton.EDU
Subject: splstdata - command fails after migration from a node

Hi *,

after the migration from one of our MCA wide nodes (AIX 4.3.3, PSSP
3.2 --> AIX 5.1_ML03, PSSP 3.5), the splstdata-commands to this one
fails.

# splstdata -b -l 1
splstdata: 0022-108 You have supplied an incorrect node: 3993.
Usage: splstdata { -A | -a | -b | -d | -g | -h | -i | -n | -s | -u
| -v | -x }
                [ -G ] [ { start_frame start_slot { node_count | rest }
                | -N node_group | -l <node_list> } ]
   OR
        splstdata { -e | -f | -p | -X }
(root:hermes_e)[/]

For all other nodes the command functions and works fine. Exactly
the same good result I get when I start the command global over all
nodes without the option '-l'

Verification test works all (SDR_test, SYSMAN_test, spmon_itest,
spmon_ctest, spmon -d, .....)

The error code means that I have a wrong node number, but this isn't so.

What can I do?

Best regards,
 Frank Mueller



This archive was generated by hypermail 2.1.7 : Wed Apr 09 2008 - 22:17:18 EDT