How to correct on TruCluster dsfmgr ERROR: sysinfo() failed: kdsreq: Device node being ACKed was not found

From: Audrius Sadlauskas (ASadlauskas@alna.lt)
Date: Thu May 27 2004 - 13:47:36 EDT


Hello,

2 of 3 clustered members (Tru64 UNIX/TruCluster V5.1A PK3) have
following error when issuing dsfmgr -v command:

Dev Nodes:
    ERROR: sysinfo() failed: kdsreq: Device node being ACKed was not
found
  Errors: 1

It seems that device database have problem.
I also found in kern.log:
" vmunix: hwc_services: failed to find device node (200000000)"

As we will need to reboot these nodes for PK6 installation, if we face
dsfmgr problem at reboot time these systems will stop at single user
mode.

Is it any possibility to fix this before rebooting?
How to safely correct this problem on TruCluster?

Thank you in advance,

Audrius Sadlauskas
Senior systems engineer

Infrastructure Solutions Centre

ALNA



This archive was generated by hypermail 2.1.7 : Sat Apr 12 2008 - 10:49:59 EDT