Cannot see my storage on GS80

From: Shah, Alay (Alay.Shah@cardinal.com)
Date: Mon Jul 29 2002 - 10:11:56 EDT


Fellow Sysadmins,

I am seeing a couple of messages from my system while trying to build a two node (Both of them are GS80s) cluster (V5.1) with Fibre Channel Storage (HSG80s). And when I boot off the CD, here are the messages I see. As a result of this, I cannot install the OS because my system is unable to see the drive, I would like to install the OS on. These systems have V6.2 of the firmware. Has anyone seen any issues with this particular version of the firmware? Apparently it doesn't have the same problem if we try and install V5.1A. I am considering going back to V6.0 of the Firmware. Any and all help will be greatly appreciated.

MESSAGE 1-

physical memory = 20480.00 megabytes.
available memory = 20114.67 megabytes.
using 26189 buffers containing 204.60 megabytes of memory
Master cpu at slot 0
Firmware revision: 6.2-602
PALcode: UNIX version 1.90-5
Compaq AlphaServer GS80 6/1001
wfqbb0 at nexus
wfiop0 at wfqbb0 slot 0
PCI device at bus 0, slot 3, function 0 could not be configured:
Vendor ID 0x10df, Device ID 0xf900, Base class 0xc, Sub class 0x4 Sub-VID 0x10df Sub-DID 0xf900
        has no matching entry in the PCI option table
pci0 (primary bus:0) at wfiop0 slot 0
isp0 at pci0 slot 1
isp0: QLOGIC ISP1040B/V2
isp0: Firmware revision 5.57 (loaded by console)
isp0: Fast RAM timing enabled.
scsi0 at isp0 slot 0 rad 0
isa0 at pci0
gpc0 at isa0
gpc1 not probed
ace0 at isa0
ace1 at isa0
lp0 at isa0
fdi0 at isa0
ata0 at pci0 slot 15
ata0: ACER M1543C
scsi1 at ata0 slot 0 rad 0
PCI device at bus 1, slot 4, function 0 could not be configured:
Vendor ID 0x10df, Device ID 0xf900, Base class 0xc, Sub class 0x4 Sub-VID 0x10df Sub-DID 0xf900
        has no matching entry in the PCI option table

Don't know what this one means....No matching entry...

MESSAGE 2-

Initializing system for Tru64 UNIX installation. Please wait...

Assigning a cluster device number to root
ccmn_trans_srm_suffix: can't translate: 3306 1 WWID:01000010:6000-1fe1-0019-fa00-0009-2150-0521-00ab
ccmn_trans_srm_suffix: can't translate: 3306 1 WWID:01000010:6000-1fe1-0019-fa00-0009-2150-0521-00ab
pccmn_trans_srm_suffix: can't translate: 3306 1 WWID:01000010:6000-1fe1-0019-fa00-0009-2150-0521-00ab
ccmn_trans_srm_suffix: can't translate: 3306 1 WWID:01000010:6000-1fe1-0019-fa00-0009-2150-0521-00ab
ccmn_trans_srm_suffix: can't translate: 3306 1 WWID:01000010:6000-1fe1-0019-fa00-0009-2150-0521-00ab
ccmn_trans_srm_suffix: can't translate: 3306 1 WWID:01000010:6000-1fe1-0019-fa00-0009-2150-0521-00ab
ccmn_trans_srm_suffix: can't translate: 3306 1 WWID:01000010:6000-1fe1-0019-fa00-0009-2150-0521-00ab
ccmn_trans_srm_suffix: can't translate: 3306 1 WWID:01000010:6000-1fe1-0019-fa00-0009-2150-0521-00ab
rom_getenv: Unable to convert 'SCSI3 0 3 0 1 0 0 0 @wwid0'
prom_getenv: Unable to convert 'SCSI3 1 4 0 3 0 0 0 @wwid0'
prom_getenv: Unable to convert 'SCSI3 0 3 0 2 0 0 0 @wwid0'

Tks & Rgds,

__________________________________________________

Alay Shah
Enterprise Technology Services
Allegiance Healthcare Corporation
1400 Waukegan Rd.
McGaw Park
IL 60085, USA
tel: 847-578-2584
fax: 847-578-5586
email: alay.shah@cardinal.com
__________________________________________________



This archive was generated by hypermail 2.1.7 : Sat Apr 12 2008 - 10:48:47 EDT