From: Tony Magtalas (ttk67@yahoo.com)
Date: Wed Jan 29 2003 - 13:06:17 EST
Sun E4000 server with 1 GB of memory. Solaris 8.
No sunvts loaded.
Question:
How does one turn on the memory-test option at boot up
time so that my server automatically test *all* of its
1 GB memory. I know it can be long, but I can wait :-)
The server is patched with the latest kernel patch
108528-18. OBP is 3.2 POST 3.9.30 (latest)
The current eeprom paramters are:
diag-switch? true
diag-level max
mfg-mode off
(btw, can you turn mfg-mode to ON for OBP=3.2?)
POST memory test appears to be very minimal
and the command ok>show-post-results showed
no memory test on the 1GB of memory at all.
memconf output:
#memconf
hostname: testsever
Sun 8-slot Sun Enterprise 4000/5000
Intrlv. Intrlv.
Brd Bank MB DIMMs Status Condition Speed
Factor With
--- ----- ---- ----- ------- ---------- -----
------- -------
0 0 1024 8x128 Active OK 60ns
1-way
Bank 0 uses sockets J3100-J3800, Bank 1 uses sockets
J3101-J3801 empty memory banks: Board 0 Bank 1 total
memory = 1024MB (1GB)
prtdiag -v output:
=========================CPUs=========================
Run Ecache CPU CPU
Brd CPU Module MHz MB Impl. Mask
--- --- ------- ----- ------ ------ ----
0 0 0 336 4.0 US-II 2.0
0 1 1 336 4.0 US-II 2.0
========================Memory=========================
Intrlv.
Intrlv.
Brd Bank MB Status Condition Speed Factor
With
--- ----- ---- ------- ---------- ----- -------
-------
0 0 1024 Active OK 60ns 1-way
========================= IO Cards
=========================
Bus Freq
Brd Type MHz Slot Name
Model
--- ---- ---- ----
--------------------------------
----------------------
1 SBus 25 2 cgsix
SUNW,501-1672
1 SBus 25 3 SUNW,hme
1 SBus 25 3 SUNW,fas/sd (block)
1 SBus 25 13 SUNW,socal/sf (scsi-3)
501-3060
3 PCI 33 1 SUNW,hme-pci108e,1001
SUNW,cheerio
3 PCI 33 3 SUNW,isptwo/sd (block)
QLGC,ISP1040B
No failures found in System
===========================
No System Faults found
======================
Most recent AC Power Failure:
=============================
Fri Jun 22 10:58:16 2001
========================= Environmental Status
========================= Keyswitch position is in
Normal Mode System Power Status: Redundant
System LED Status: GREEN YELLOW GREEN
Normal ON OFF BLINKING
Fans:
-----
Unit Status
---- ------
Rack OK
Key OK
AC OK
System Temperatures (Celsius):
------------------------------
Brd State Current Min Max Trend
--- ------- ------- --- --- -----
0 OK 39 38 39 stable
1 OK 41 41 42 stable
3 OK 38 38 39 stable
CLK OK 29 29 29 stable
Power Supplies:
---------------
Supply Status
--------- ------
0 OK
1 OK
3 OK
PPS OK
System 3.3v OK
System 5.0v OK
Peripheral 5.0v OK
Peripheral 12v OK
Auxilary 5.0v OK
Peripheral 5.0v precharge OK
Peripheral 12v precharge OK
System 3.3v precharge OK
System 5.0v precharge OK
AC Power OK
========================= HW Revisions
=========================
ASIC Revisions:
---------------
Brd FHC AC SBus0 SBus1 PCI0 PCI1 FEPS Board
Type Attributes
--- --- -- ----- ----- ---- ---- ----
---------- ----------
0 1 5 CPU
84MHz Capable
1 1 5 1 1 22
Dual-SBus-SOC+ 100MHz Capable
3 1 5 4 4 c1 Dual-PCI
100MHz Capable
System Board PROM revisions:
----------------------------
Board 0: OBP 3.2.30 2002/10/25 14:03 POST
3.9.30 2002/10/25 14:04
Board 1: FCODE 1.8.30 2002/10/25 14:02 iPOST
3.4.30 2002/10/25 14:03
Board 3: FCODE 1.8.30 2002/10/25 14:02 iPOST
3.0.30 2002/10/25 14:03
Many thanks for your feedback
Tony
Yahoo! Mail Plus - Powerful. Affordable. Sign up now.
http://mailplus.yahoo.com
_______________________________________________
sunmanagers mailing list
sunmanagers@sunmanagers.org
http://www.sunmanagers.org/mailman/listinfo/sunmanagers
This archive was generated by hypermail 2.1.7 : Wed Apr 09 2008 - 23:25:44 EDT