From: Grimland, Courtney (grimland@uta.edu)
Date: Tue Apr 08 2008 - 14:22:15 EDT
This morning I started seeing a bunch of these on one of my SE3310's:
# sccli c3t0d0s2 show events
<snip>
Tue Apr 8 11:34:14 2008
[1113] #767: StorEdge Array SN#13940 CH0 ID2: SCSI Drive ALERT: bad
block encountered (02h, 03h,11/00)
<snip>
All of the messages are for the same block (02h, 03h,11/00). Is this a
reason to replace a disk, or are bad blocks a normal part of disk
operation? I've never seen the messages before.