hang at ok prompt

From: Hermawan S (hermawansv@gmail.com)
Date: Fri Jul 21 2006 - 23:49:35 EDT


Hi Managers,

I have a little problem with Sun Enterprise 450 server.
when i turn it on, the led for "general fault" always blinking rapidly and
led is orange.

i change the nvram parameter at OK prompt to view some error messages
setenv diag-level max
setenv diag-switch? true
setenv auto-boot? false
reset-all

below the message after i change the nvram parameter.

1>@(#) Sun UltraSPARC-II 4-way UPA/PCI POST 6.1.0 12/20/00: 16:32
1>INFO: Processor 1 is master CPU.
1>INFO: Motherboard rev FCS
1>
1> <00> Init System BSS
1> <00> NVRAM Battery Detect Test
1> <00> NVRAM Scratch Addr Test
1> <00> DMMU TLB Tag Access Test
1> <00> DMMU TLB RAM Access Test
1> <00> Probe Ecache
1>INFO: 8192KB Ecache
1> <00> Ecache RAM Addr Test
1> <00> Ecache Tag Addr Test
1> <00> Invalidate Ecache Tags
1> <00> SC Dtag Probe
1>INFO: Dtag supports up to 8MB Ecache
1>INFO: Processor 0 is missing or disabled.
1>INFO: Processor 2 is missing or disabled.
1>INFO: Processor 3 - UltraSPARC-II.
1> <00> Init SC Regs
1> <00> SC Address Reg Test
1> <00> SC Reg Index Test
1> <00> SC Regs Test
1> <00> SC Dtag RAM Addr Test
1> <00> SC Dtag Init
1> <00> Init SC Regs
1> <00> SC Cache Size Init
3> <00> Probe Ecache
3>INFO: 8192KB Ecache
3> <00> Ecache RAM Addr Test
3> <00> Ecache Tag Addr Test
3> <00> Invalidate Ecache Tags

then stop..

any idea how to fix it ??

Regards

Hermawan S