Lost half of my 3510 !

From: Rob McMahon (Rob.McMahon@warwick.ac.uk)
Date: Fri May 12 2006 - 12:00:19 EDT


OK, I've got a nasty one here. I have a 3510, connected to a V890
running Solaris 10, with 2 RAID 5 partitions and one of them has gone
away! format says

       0. c6t600C0FF0000000000855611A253F4800d0 <drive not available>
          /scsi_vhci/ssd@g600c0ff0000000000855611a253f4800

sccli> show log
LD LD-ID Size Assigned Type Disks Spare Failed Status
------------------------------------------------------------------------
ld0 3BE6F2D9 545.91GB Primary RAID5 5 2 0 Good
                         Write-Policy Default StripeSize 32KB
ld1 1A253F48 545.91GB Secondary RAID5 5 2 0 Good
                         Write-Policy Default StripeSize 32KB
sccli> show luns
Ch Tgt LUN ld/lv ID-Partition Assigned Filter Map
--------------------------------------------------------------
 0 40 0 ld0 3BE6F2D9-00 Primary
 1 42 1 ld1 1A253F48-00 Secondary
 4 44 1 ld0 3BE6F2D9-00 Primary
 5 46 0 ld1 1A253F48-00 Secondary
sccli> show redundancy-mode
 Primary controller serial number: 8040592
 Primary controller location: Lower
 Redundancy mode: Active-Active
 Redundancy status: Detected
 Secondary controller serial number: 0
sccli>

Redundancy status: Detected ? Why not enabled ?

In messages it says:

May 11 11:32:07 narcissus fp: [ID 517869 kern.info] NOTICE: fp(5): PLOGI
to 9d failed state=Packet Transport error, reason=No Connection
May 11 11:32:07 narcissus fctl: [ID 517869 kern.warning] WARNING:
fp(5)::PLOGI to 9d failed. state=e reason=5.
May 11 11:32:07 narcissus scsi: [ID 243001 kern.warning] WARNING:
/pci@9,600000/SUNW,qlc@1,1/fp@0,0 (fcp5):
May 11 11:32:07 narcissus PLOGI to D_ID=0x9d failed: State:Packet
Transport error, Reason:No Connection. Giving up
May 11 11:32:07 narcissus fp: [ID 517869 kern.info] NOTICE: fp(0): PLOGI
to a5 failed state=Packet Transport error,reason=No Connection
May 11 11:32:07 narcissus fctl: [ID 517869 kern.warning] WARNING:
fp(0)::PLOGI to a5 failed. state=e reason=5.
May 11 11:32:07 narcissus scsi: [ID 243001 kern.warning] WARNING:
/pci@9,600000/SUNW,qlc@2/fp@0,0 (fcp0):
May 11 11:32:07 narcissus PLOGI to D_ID=0xa5 failed: State:Packet
Transport error, Reason:No Connection. Giving up
May 11 11:32:07 narcissus qlc: [ID 686697 kern.info] NOTICE: Qlogic
qlc(3): Loop OFFLINE
May 11 11:32:07 narcissus qlc: [ID 686697 kern.info] NOTICE: Qlogic
qlc(2): Loop OFFLINE
May 11 11:32:07 narcissus qlc: [ID 686697 kern.info] NOTICE: Qlogic
qlc(2): Loop ONLINE
May 11 11:32:24 narcissus qlc: [ID 686697 kern.info] NOTICE: Qlogic
qlc(3): Loop ONLINE
May 11 11:34:03 narcissus scsi: [ID 243001 kern.warning] WARNING:
/pci@9,600000/SUNW,qlc@1,1/fp@0,0 (fcp5):
May 11 11:34:03 narcissus REPORT LUN to D_ID=0x9d lun=0x0 failed:
State:Timeout, Reason:Hardware Error. Giving up
May 11 11:34:03 narcissus scsi: [ID 243001 kern.info]
/pci@9,600000/SUNW,qlc@1,1/fp@0,0 (fcp5):
May 11 11:34:03 narcissus offlining lun=0 (trace=0), target=9d
(trace=810101)
May 11 11:34:03 narcissus genunix: [ID 834635 kern.info]
/scsi_vhci/ssd@g600c0ff0000000000855611a253f4800 (ssd30) multipath
status: degraded, path /pci@9,600000/SUNW,qlc@1,1/fp@0,0 (fp5) to target
address: w266000c0ffe85561,0 is offline Load balancing: round-robin
May 11 11:34:20 narcissus scsi: [ID 243001 kern.warning] WARNING:
/pci@9,600000/SUNW,qlc@2/fp@0,0 (fcp0):
May 11 11:34:20 narcissus REPORT LUN to D_ID=0xa5 lun=0x0 failed:
State:Timeout, Reason:Hardware Error. Giving up
May 11 11:34:20 narcissus scsi: [ID 243001 kern.info]
/pci@9,600000/SUNW,qlc@2/fp@0,0 (fcp0):
May 11 11:34:20 narcissus offlining lun=1 (trace=0), target=a5
(trace=810101)
May 11 11:34:20 narcissus scsi: [ID 243001 kern.info]
/pci@9,600000/SUNW,qlc@2/fp@0,0 (fcp0):
May 11 11:34:20 narcissus offlining lun=0 (trace=0), target=a5
(trace=810101)
May 11 11:34:20 narcissus genunix: [ID 834635 kern.info]
/scsi_vhci/ses@g600c0ff0000000000855610000000000 (ses4) multipath
status: degraded, path /pci@9,600000/SUNW,qlc@2/fp@0,0 (fp0) to target
address: w226000c0ffa85561,0 is offline Load balancing: round-robin
May 11 11:34:20 narcissus scsi: [ID 107833 kern.warning] WARNING:
/scsi_vhci/ssd@g600c0ff0000000000855611a253f4800 (ssd30):
May 11 11:34:20 narcissus transport rejected fatal error
May 11 11:34:23 narcissus scsi: [ID 107833 kern.warning] WARNING:
/scsi_vhci/ssd@g600c0ff0000000000855611a253f4800 (ssd30):
May 11 11:34:23 narcissus offline

All the links look okay, the only lights are green.

Can someone suggest how to get my volume back. I hope there's enough
information here. Obviously I'll put in a support call, but can I get
the redundancy to kick in, or get my second controller back ?

Any suggestions gratefully received.

Cheers,

Rob

-- 
E-Mail:	Rob.McMahon@warwick.ac.uk		PHONE:  +44 24 7652 3037
Rob McMahon, IT Services, Warwick University, Coventry, CV4 7AL, England