Re: RE: pl. tell me the procedure to replace the rootmirror disk

From: vikas bhargava (vikas_bhargava@rediffmail.com)
Date: Thu Sep 08 2005 - 09:05:36 EDT


 hi,

Thanks to all to helped me on this.
Whiat i did was: I just shutdown the
server & replace the faulty HDD & then I run "vxdctl enable" so that veritas
recognise the new HDD then I run vxdiskadm & then select option 4 & then
option 5.

this was the process to replace the HDD.

regards
vikas

On Wed,
07 Sep 2005 George Monappallil wrote :
>Vikas:
>Any replies to this yet. Your
summary would greatly benefit the board.
>Thanks,
>
>-George
>
>-----Original
Message-----
> From: sunmanagers-bounces@sunmanagers.org
>[mailto:sunmanagers-bounces@sunmanagers.org] On Behalf Of vikas bhargava
>Sent: Monday, September 05, 2005 2:59 AM
>To: sunmanagers@sunmanagers.org
>Subject: pl. tell me the procedure to replace the rootmirror disk
>
>
>hi Sun
managers,
>
>I've a Sunfire V480 server. & veritas volume manager is installed
in the
>server. So now one of it disk has failed which is the rootmirror.
>
>Can any one tell me the procedure of replacing the rootmirror disk.
>
>
>Thanks & regards
>vikas
>_______________________________________________
>sunmanagers mailing list
>sunmanagers@sunmanagers.org
>http://www.sunmanagers.org/mailman/listinfo/sunmanagers
_______________________________________________
sunmanagers mailing list
sunmanagers@sunmanagers.org
http://www.sunmanagers.org/mailman/listinfo/sunmanagers