SUMMARY: Ultra 10 Power Module

From: Fiengo, Paul (Contractor) (Paul.Fiengo.ctr@disa.mil)
Date: Tue Sep 06 2005 - 09:10:16 EDT


All,

Sorry for the delay in posting a summary in regards to this subject. Most
all gurus advised that the power modules are auto-sensing for 110-220V
power. What I found also is if you remove the power supply unit from the
chassis, it states directly on the power supply unit whether or not it is
auto-sensing. Thank you to all who responded.

Original Post:

>All Gurus,
>
>I have a number of Ultra 10 workstations deployed to various sites and have
>a question regarding the power supplies. On the back of the Ultra 10
>workstations some have a red switch that allows the system administrator to
>switch between 110V and 220V. Other Ultra 10 workstations do not have this
>switch. My question is this, the Ultra 10 workstations that do not have
>this red switch, are they straight 110V power supplies or are they
>auto-sensing power supplies. Any information would greatly be appreciated.

Paul Fiengo
_______________________________________________
sunmanagers mailing list
sunmanagers@sunmanagers.org
http://www.sunmanagers.org/mailman/listinfo/sunmanagers



This archive was generated by hypermail 2.1.7 : Wed Apr 09 2008 - 23:31:32 EDT