From: Richard Skelton (Richard.Skelton@infineon.com)
Date: Thu Jun 23 2005 - 05:26:43 EDT
Hi Manager,
I have just built an E4500 with one CPU board, one clock board, one IO
board and a disk board with on disk
After installing Solaris 8 and running VTS over night the disk board is
in low power mode ( amber led on )
Solaris 8 Recommended Patch Cluster from May/10/05 installed
The output from prtdiag -v :-
System Configuration: Sun Microsystems sun4u 8-slot Sun Enterprise
E4500/E5500
System clock frequency: 100 MHz
Memory size: 2048Mb
========================= CPUs =========================
Run Ecache CPU CPU
Brd CPU Module MHz MB Impl. Mask
--- --- ------- ----- ------ ------ ----
5 10 0 400 8.0 US-II 10.0
5 11 1 400 8.0 US-II 10.0
========================= Memory =========================
Intrlv. Intrlv.
Brd Bank MB Status Condition Speed Factor With
--- ----- ---- ------- ---------- ----- ------- -------
5 0 1024 Active OK 60ns 2-way A
5 1 1024 Active OK 60ns 2-way A
========================= IO Cards =========================
Bus Freq
Brd Type MHz Slot Name Model
--- ---- ---- ---------- ----------------------------
--------------------
1 SBus 25 0 network
SUNW,sbus-gem
1 SBus 25 3
SUNW,hme
1 SBus 25 3 SUNW,fas/sd
(block)
1 SBus 25 13 SUNW,socal/sf (scsi-3)
501-3060
Detached Boards
===============
Slot State Type Info
---- --------- ------ -----------------------------------------
7 disabled disk Disk 0: no disk Disk 1: Target:
15
No failures found in System
===========================
No System Faults found
======================
Most recent AC Power Failure:
=============================
Sat Sep 8 14:39:55 2001
========================= Environmental Status =========================
Keyswitch position is in Diagnostic Mode
System Power Status: Redundant
System LED Status: GREEN YELLOW GREEN
Normal ON OFF BLINKING
Fans:
-----
Unit Status
---- ------
Rack OK
Key OK
AC OK
System Temperatures (Celsius):
------------------------------
Brd State Current Min Max Trend
--- ------- ------- --- --- -----
1 OK 36 35 36 stable
5 OK 31 28 33 stable
CLK OK 26 25 27 stable
Power Supplies:
---------------
Supply Status
--------- ------
0 OK
1 OK
3 OK
PPS OK
System 3.3v OK
System 5.0v OK
Peripheral 5.0v OK
Peripheral 12v OK
Auxilary 5.0v OK
Peripheral 5.0v precharge OK
Peripheral 12v precharge OK
System 3.3v precharge OK
System 5.0v precharge OK
AC Power OK
========================= HW Revisions =========================
ASIC Revisions:
---------------
Brd FHC AC SBus0 SBus1 PCI0 PCI1 FEPS Board Type Attributes
--- --- -- ----- ----- ---- ---- ---- ---------- ----------
1 1 5 1 1 22 Dual-SBus-SOC+ 100MHz Capable
5 1 5 CPU 100MHz Capable
7 Unknown 100MHz Capable
System Board PROM revisions:
----------------------------
Board 1: FCODE 1.8.30 2002/10/25 14:02 iPOST 3.4.30 2002/10/25 14:03
Board 5: OBP 3.2.30 2002/10/25 14:03 POST 3.9.30 2002/10/25 14:04
Does the disk board not have a PROM?
Why is the disk board identified as "Detached/disabled" ?
The system seem to work fine :-)
-- Cheers Richard Skelton Richard.Skelton@infineon.com Infineon Technologies UK Ltd Infineon House Great Western Court Hunts Ground Road Stoke Gifford Bristol BS34 8HP Tel +44(0)117 9528808 _______________________________________________ sunmanagers mailing list sunmanagers@sunmanagers.org http://www.sunmanagers.org/mailman/listinfo/sunmanagers