Strange Sbus ge network fault on E3500

From: Richard Skelton (Richard.Skelton@infineon.com)
Date: Mon May 09 2005 - 05:26:52 EDT


Hi,
One of our E3500 had a panic on Saturday afternoon and when it rebooted
it could not fine the ge0.
Today I power cycled the machine and it came up first time.
Do I have a ge Sbus board on the way out?
Here is part of the console output:-
WARNING: [AFT1] Timeout on System Bus in privileged mode from CPU6 Data
access at TL=0, errID 0x000b15ef.e65e1fc3
    AFSR 0x00000000.88000000<PRIV,TO> AFAR 0x000001c7.00209000
    AFSR.PSYND 0x0000(Score 05) AFSR.ETS 0x00 Fault_PC 0x1030913c
    UDBH 0x0000 UDBH.ESYND 0x00 UDBL 0x0000 UDBL.ESYND 0x00
 
 panic[cpu6]/thread=2a100097d20: [AFT1] errID 0x000b15ef.e65e1fc3 BTO
Error(s)
    See previous message(s) for details
 
000002a100097200 SUNW,UltraSPARC-II:cpu_aflt_log+568 (2a1000972be, 1,
10155300, 2a100097448, 2a10009730b, 10155328)
  %l0-3: 0000000000000000 0000000000000003 000002a100097510
0000000000000010
  %l4-7: 0000000000000000 0000000000000000 000000001041cb60
0000000000000001
000002a100097450 SUNW,UltraSPARC-II:cpu_async_error+868 (88000000,
2a100097510, 88000000, 8000000, 640000088000000, 2a1000976d0)
  %l0-3: 0000000000000001 0000000000000032 0000000000000000
0000000000000000
  %l4-7: 0000000000000219 0000000000000000 000000001041cb60
0000030001b03ed0
000002a100097620 unix:prom_rtt+0 (1c85a24, 30002b25004, 20, 3,
300001890c0, 10079638)
  %l0-3: 0000000000000004 0000000000001400 0000000080001603
000000001014c848
  %l4-7: 00000300001b98c8 0000030001b03ea8 0000000000000000
000002a1000976d0
000002a100097770 ge:ge_pcs_read+28 (30002b14000, 4, 2a1000978d8,
2a100097d20, bfffffffc720482a, 0)
  %l0-3: 0000030002b19270 0000030002b170e8 000000000000000a
000000001000a408
  %l4-7: 00000300001b98c8 0000030001b03ea8 0000000000000000
000002a100165740
000002a100097820 ge:ge_check_pcs_link+12c (30002b19358, 5000,
30002b14000, 1, 0, 1041c3f8)
  %l0-3: 000000001030910c 0000000000000016 000000000000000a
000000001000a408
  %l4-7: 00000310031bc230 0000030001b03ea8 0000000000000000
000002a10001f910
000002a1000978e0 ge:ge_check_link+74 (30002b14000, 5000, 30002b14000,
10424d30, 16, 0)
  %l0-3: 000000001030fc40 00000310081678a0 0000000000000000
000002a10001fd20
  %l4-7: 0000000000000000 000003000f2da578 0000000000000000
000002a1001658b0
000002a100097990 genunix:callout_execute+90 (bfffffffc720482a, 1,
30000257038, 1298fa11, 30000256038, 0)
  %l0-3: 0000000010310f04 8000000000000000 0000000000000009
00000300002570c0
  %l4-7: 000000001298fa11 0000030000256000 00000300046fb400
000002a1000979a0
000002a100097a40 genunix:taskq_thread+18c (30001b0fd90, 0, 10424d30,
10000, 30001b0fdc2, 30001b0fde8)
  %l0-3: 0000000010078420 0000030001b0fdc0 0000030001b0fdb8
0000030001b0fd90
  %l4-7: 0000030001b0fdb0 0000030001b09e68 000000000000000c
0000000000000006
 
syncing file systems... 2 done
dumping to /dev/dsk/c0t1d0s1, offset 2577006592
   1% done 100% done: 82465 pages dumped, compression ratio 2.65, dump
succeeded
rebooting...
Resetting...
Software Power ON
.
.
.
     POST COMPLETE
 3,0>Entering OBP
 
ttya initialized
Using POST's System Configuration
Setting up memory
Starting CPU ID 7
Starting CPU ID 10
Starting CPU ID 11
Starting CPU ID 14
Starting CPU ID 15
Starting CPU ID 18
Starting CPU ID 19
fhc ac simm-status environment sram flashprom SUNW,UltraSPARC-II
SUNW,UltraSPARC
-II
fhc ac simm-status environment sram flashprom SUNW,UltraSPARC-II
SUNW,UltraSPARC
-II
fhc ac simm-status environment sram flashprom SUNW,UltraSPARC-II
SUNW,UltraSPARC
-II
fhc ac simm-status environment sram flashprom SUNW,UltraSPARC-II
SUNW,UltraSPARC
-II
Probing UPA Slot at 2,0 sbus fhc ac environment flashprom eeprom
sbus-speed co
unter-timer
Probing UPA Slot at 3,0 sbus counter-timer
Probing /sbus@2,0 at d,0 SUNW,socal sf ssd sf ssd
Probing /sbus@2,0 at 1,0 Nothing there
Probing /sbus@2,0 at 2,0 Nothing there
Probing /sbus@3,0 at 3,0 SUNW,hme SUNW,fas sd st
Probing /sbus@3,0 at 0,0 Invalid FCode start byte at ffd46000

5-slot Sun Enterprise E3500, No Keyboard
OpenBoot 3.2.30, 8192 MB memory installed, Serial #11438264.

Rebooting with command: boot
 
Port#0 received soc-status=14 loop 0 is ONLINE
Boot device: disk File and args:
Loading ufs-file-system package 1.4 04 Aug 1995 13:02:54
FCode UFS Reader 1.11 97/07/10 16:19:15.
Loading: /platform/SUNW,Ultra-Enterprise/ufsboot
Loading: /platform/sun4u/ufsboot
SunOS Release 5.8 Version Generic_117350-16 64-bit
Copyright 1983-2003 Sun Microsystems, Inc. All rights reserved.
ifconfig: plumb: ge0: Bad file number
moving addresses from failed IPv4 interfaces: ge0 (couldn't move, no
alternative interface).

-- 
Cheers
Richard Skelton
Richard.Skelton@infineon.com
Infineon Technologies UK Ltd
Infineon House
Great Western Court
Hunts Ground Road
Stoke Gifford
Bristol
BS34 8HP
Tel +44(0)117 9528808
_______________________________________________
sunmanagers mailing list
sunmanagers@sunmanagers.org
http://www.sunmanagers.org/mailman/listinfo/sunmanagers