From: Mohammed Sajid (msajidp@emirates.net.ae)
Date: Sat Nov 20 2004 - 11:25:01 EST
Hi ,
I have an UPDATE on this problem posted few days back.
I have simulated the scenario on another V880 and found that NIS+ Server is
the culprit. Immediately after installing the NIS+ server tried INIT 6 and
the systems hung.
Any clue?
Thanks for those responded.
Regards,
----------------------------------------------------------------------------
----------------------------------------------------------------------------
------------------------
Hi everyone,
I am having yet another problem today. I have posted a similar problem a
year back and never got a proper solution.
Now on my new V880 server also same problem started appearing.
The problem is system hangs when init 6 or init 5 or init 0 or shutdown is
issued. It gives the message going down on signal 15 and hangs.
I have to do stop A and boot the machine. Obviously, most of the times I
have to do FSCK on root file system.
Any idea why the systems hangs during shutdown? How can I find out at what
stage it hangs? Is there any debug option?
The system configuration is as follows:
V880 - 4 CPU - 8 GB RAM
Storage : 3510 Storadge - 1.7 TB on Q-Logic HBA
IBM ESS SAN connected on Q - Logic HBA
IBM SDD Installed for Virtual Pathing
NIS+ Root Server
TSM Backup Client Installed.
I have a suspicion that after installing NIS+ it started behaving this way.
Does anyone face similar problem?
I know I can remove the NIS+ and check but system is already in production.
So, would like to know before doing that.
Regards,
Sajid