I just want to say thanks to all that replied.

 Here are the steps

download SAN_4.2a_install_it.tar.Z
zcat SAN_4.2a_install_it.tar.Z |tar xvf -
cd SAN_4.2a_install_it/
./install_it
reboot -- -r

When server comes up then follow the next steps

devfsadm -v
luxadm -e port
luxadm -e dump_map /devices/pci@1c,600000/SUNW,qlc@1/fp@0,0:devctl
cfgadm -l
cfgadm -c configure cX (X=container ID)

Wolfgang Schwurack wrote:

> Hi All
>
> PROBLEM DESCRIPTION:
> Can not see StorEdge 3510 from OS. I am current on all patches. I
> installed san software SAN_4.2a_install_it. At the ok prompt I type in
> probe-scsi-all I get this, which see the storedge 3510
>
> /pci@1d,700000/SUNW,qlc@1
> ************************* Fabric Attached Devices
> ************************
> Adapter portId - 20e00 Device PortId 20000 DeviceId 3 WWPN
> 266000c0ffe03a3b
> Lun 0 DISK SUN StorEdge 3510 327P
>
> Device PortId 20500 DeviceId 1 WWPN 210000e08b0e4a5e
>
>
> Device PortId 40655 DeviceId 6 WWPN 50060b0000204828
> Lun 0 TAPE HP Ultrium 2-SCSI K342
>
>
>
> /pci@1c,600000/SUNW,qlc@1
> ************************* Fabric Attached Devices
> ************************
> Adapter portId - 10e00 Device PortId 10000 DeviceId 2 WWPN
> 216000c0ff803a3b
> Lun 0 DISK SUN StorEdge 3510 327P
>
>
> Device PortId 10100 DeviceId 3 WWPN 226000c0ffa03a3b
> Lun 0 DISK SUN StorEdge 3510 327P
>
>
>
> Device PortId 30000 DeviceId 7 WWPN 500104f0006e4c90
> Lun 0 CHANGER STK L180 0306
>
>
> Device PortId 30655 DeviceId 8 WWPN 50060b0000204934
> Lun 0 TAPE HP Ultrium 2-SCSI K342
>
> At the OS level I type format and I only see the local drives
>
> # format
> Searching for disks...done
>
>
> AVAILABLE DISK SELECTIONS:
> 0. c1t0d0 <SUN36G cyl 24620 alt 2 hd 27 sec 107>
> /pci@1f,700000/scsi@2/sd@0,0
> 1. c1t1d0 <SUN36G cyl 24620 alt 2 hd 27 sec 107>
> /pci@1f,700000/scsi@2/sd@1,0
> 2. c1t2d0 <SUN36G cyl 24620 alt 2 hd 27 sec 107>
> /pci@1f,700000/scsi@2/sd@2,0
> 3. c1t3d0 <SUN36G cyl 24620 alt 2 hd 27 sec 107>
> /pci@1f,700000/scsi@2/sd@3,0
>
> I have done this on other server that are V480 that work just fine,
> but on the two V440's I can not see the storedge 3510
>
>
> Thanks
>

-- 
      0___      Wolfgang Schwurack
     c/  /'_    Unix System Administrator
    (*)  \(*)   University of Utah/Utah Education Network
                Tel: (801) 587-9444
                email: wolf@uen.org
_______________________________________________
sunmanagers mailing list
sunmanagers@sunmanagers.org
http://www.sunmanagers.org/mailman/listinfo/sunmanagers


This archive was generated by hypermail 2.1.7 : Wed Apr 09 2008 - 23:29:13 EDT