One small Problem in sharing Storage between two servers... Please Help me

From: manoj ghag (manojghag@rediffmail.com)
Date: Wed May 12 2004 - 07:52:39 EDT


  
Hi, All

I am facing one small problem in attaching the storage to second
sun server
(I want to share or make available this D1000 Storage between two
Sun servers)

Please find the output for device information of our two sun
servers

Please consider that main problem our case is ....
We have Two Sun
Servers ( sun1 and sun2) with One D1000 Storage Box

we have attached on -->
Sun2 <-- Server and it is working fine and I have created some volumns also on
that , but when we try
to attach the Storage to Second Sun server --> Sun1
<--

But in this case it doesn't show the storage Disk attache to Solaris
server 2 ( Nor in fdisk or not in Format command also)
Storage D1000
                         / \
/ \
                       / \
                     Sun2
Sun1
 

We have Terminator attached to both the servers

other information is
as follows

( So please kindly look at it and tell me your comments for the
same)

-------------------------
sun2 Server output
------------------------
bash-2.03# /usr/platform/sun4u/sbin/prtdiag -v

System Configuration: Sun
Microsystems sun4u Sun Enterprise 420R (4 X UltraSPA
RC-II 450MHz)
System
clock frequency: 113 MHz
Memory size: 4096 Megabytes
========================= CPUs =========================
Run Ecache CPU CPU
Brd CPU Module MHz MB Impl. Mask

---
---  -------  -----  ------  ------  ----
 0     0     0      450     4.0
US-II    10.0
 0     1     1      450     4.0   US-II    10.0
 0     2     2
450     4.0   US-II    10.0
 0     3     3      450     4.0   US-II    10.0
========================= IO Cards =========================
     Bus   Freq
Brd  Type  MHz   Slot        Name                              Model
---  ----
----  ----------  --------------------------------  -----------------
-----
 0
PCI    33     On-Board  network-SUNW,hme
 0   PCI    33     On-Board
scsi-glm/disk (block)             Symbios,53C875
 0   PCI    33     On-Board
scsi-glm/disk (block)             Symbios,53C875
 0   PCI    33   pcib slot 2
TSI,gfxp                          GFXP
 0   PCI    33   pcib slot 4
pci-pci1011,25/pci108e,1000       pci-bridge
 0   PCI    33   pcib slot 4
SUNW,qfe-pci108e,1001             SUNW,pci-qfe
 0   PCI    33   pcib slot 4
SUNW,qfe-pci108e,1001             SUNW,pci-qfe
 0   PCI    33   pcib slot 4
SUNW,qfe-pci108e,1001             SUNW,pci-qfe
 0   PCI    33   pcib slot 4
SUNW,qfe-pci108e,1001             SUNW,pci-qfe
 0   PCI    33   pcia slot 1
scsi-glm/disk (block)             Symbios,53C875
 0   PCI    33   pcia slot 1
scsi-glm/disk (block)             Symbios,53C875
No failures found in System
===========================
========================= HW Revisions
=========================
ASIC Revisions:
---------------
PCI: pci Rev 4
PCI:
pci Rev 4
Cheerio: ebus Rev 1
System PROM revisions:
----------------------
OBP 3.23.0 1999/06/30 13:53   POST 1.2.7 1999/05/24 17:33
bash-2.03# df -k
Filesystem            kbytes    used   avail capacity  Mounted on
/dev/dsk/c0t0d0s0     106399   89352    6408    94%    /
/dev/dsk/c0t0d0s6
1477587  828806  589678    59%    /usr
/proc                      0       0
0     0%    /proc
fd                         0       0       0     0%
/dev/fd
mnttab                     0       0       0     0%    /etc/mnttab
/dev/dsk/c0t0d0s3      49723   31797   12954    72%    /var
swap
335992      24  335968     1%    /var/run
swap                  335992      24
335968     1%    /tmp
/dev/dsk/c0t1d0s7    35009161 28767416 5891654    84%
/export/home0
/dev/dsk/c0t0d0s7    14697143 13910581  639591    96%
/export/home
/dev/dsk/c0t0d0s1     759163  267830  430600    39%
/usr/openwin
bash-2.03#
---------------------------------
Sun1 Server
--------------------------------
login: root
Password:
Last login: Mon May 10
13:34:09 from free.elite.co.in
Sun Microsystems Inc.   SunOS 5.8       Generic
Patch   October 2001
You have new mail.
# bash
bash-2.03#
/usr/platform/sun4u/sbin/prtdiag -v
System Configuration:  Sun Microsystems
sun4u Sun Enterprise 420R (4 X UltraSPA
RC-II 450MHz)
System clock frequency:
113 MHz
Memory size: 4096 Megabytes
========================= CPUs
=========================
                    Run   Ecache   CPU    CPU
Brd
CPU   Module   MHz     MB    Impl.   Mask
---  ---  -------  -----  ------
------  ----
 0     0     0      450     4.0   US-II    10.0
 0     1     1
450     4.0   US-II    10.0
 0     2     2      450     4.0   US-II    10.0
 0
3     3      450     4.0   US-II    10.0
========================= IO Cards
=========================
     Bus   Freq
Brd  Type  MHz   Slot        Name
Model
---  ----  ----  ----------  --------------------------------
-----------------
-----
 0   PCI    33     On-Board  network-SUNW,hme
 0
PCI    33     On-Board  scsi-glm/disk (block)             Symbios,53C875
 0
PCI    33     On-Board  scsi-glm/disk (block)             Symbios,53C875
 0
PCI    33   pcib slot 4  scsi-glm/disk (block)             Symbios,53C875
 0
PCI    33   pcib slot 4  scsi-glm/disk (block)             Symbios,53C875
 0
PCI    33   pcia slot 1  pci-pci1011,25.4/pci108e,1000     pci-bridge
 0
PCI    33   pcia slot 1  SUNW,qfe-pci108e,1001             SUNW,pci-qfe
 0
PCI    33   pcia slot 1  SUNW,qfe-pci108e,1001             SUNW,pci-qfe
 0
PCI    33   pcia slot 1  SUNW,qfe-pci108e,1001             SUNW,pci-qfe
 0
PCI    33   pcia slot 1  SUNW,qfe-pci108e,1001             SUNW,pci-qfe
No
failures found in System
===========================
========================= HW Revisions =========================
ASIC
Revisions:
---------------
PCI: pci Rev 4
PCI: pci Rev 4
Cheerio: ebus Rev 1
System PROM revisions:
----------------------
  OBP 3.29.0 2000/12/20 18:40
POST 1.2.8 2000/08/22 19:50
bash-2.03#
-------------------------
sun2 Server output
------------------------
bash-2.03# /usr/platform/sun4u/sbin/prtdiag -v
System Configuration:  Sun
Microsystems  sun4u Sun Enterprise 420R (4 X UltraSPA
RC-II 450MHz)
System
clock frequency: 113 MHz
Memory size: 4096 Megabytes
========================= CPUs =========================
Run   Ecache   CPU    CPU
Brd  CPU   Module   MHz     MB    Impl.   Mask
---
---  -------  -----  ------  ------  ----
 0     0     0      450     4.0
US-II    10.0
 0     1     1      450     4.0   US-II    10.0
 0     2     2
450     4.0   US-II    10.0
 0     3     3      450     4.0   US-II    10.0
========================= IO Cards =========================
     Bus   Freq
Brd  Type  MHz   Slot        Name                              Model
---  ----
----  ----------  --------------------------------  -----------------
-----
 0
PCI    33     On-Board  network-SUNW,hme
 0   PCI    33     On-Board
scsi-glm/disk (block)             Symbios,53C875
 0   PCI    33     On-Board
scsi-glm/disk (block)             Symbios,53C875
 0   PCI    33   pcib slot 2
TSI,gfxp                          GFXP
 0   PCI    33   pcib slot 4
pci-pci1011,25/pci108e,1000       pci-bridge
 0   PCI    33   pcib slot 4
SUNW,qfe-pci108e,1001             SUNW,pci-qfe
 0   PCI    33   pcib slot 4
SUNW,qfe-pci108e,1001             SUNW,pci-qfe
 0   PCI    33   pcib slot 4
SUNW,qfe-pci108e,1001             SUNW,pci-qfe
 0   PCI    33   pcib slot 4
SUNW,qfe-pci108e,1001             SUNW,pci-qfe
 0   PCI    33   pcia slot 1
scsi-glm/disk (block)             Symbios,53C875
 0   PCI    33   pcia slot 1
scsi-glm/disk (block)             Symbios,53C875
No failures found in System
===========================
========================= HW Revisions
=========================
ASIC Revisions:
---------------
PCI: pci Rev 4
PCI:
pci Rev 4
Cheerio: ebus Rev 1
System PROM revisions:
----------------------
OBP 3.23.0 1999/06/30 13:53   POST 1.2.7 1999/05/24 17:33
bash-2.03# df -k
Filesystem            kbytes    used   avail capacity  Mounted on
/dev/dsk/c0t0d0s0     106399   89352    6408    94%    /
/dev/dsk/c0t0d0s6
1477587  828806  589678    59%    /usr
/proc                      0       0
0     0%    /proc
fd                         0       0       0     0%
/dev/fd
mnttab                     0       0       0     0%    /etc/mnttab
/dev/dsk/c0t0d0s3      49723   31797   12954    72%    /var
swap
335992      24  335968     1%    /var/run
swap                  335992      24
335968     1%    /tmp
/dev/dsk/c0t1d0s7    35009161 28767416 5891654    84%
/export/home0
/dev/dsk/c0t0d0s7    14697143 13910581  639591    96%
/export/home
/dev/dsk/c0t0d0s1     759163  267830  430600    39%
/usr/openwin
bash-2.03#
---------------------------------
Sun1 Server
--------------------------------
login: root
Password:
Last login: Mon May 10
13:34:09 from free.elite.co.in
Sun Microsystems Inc.   SunOS 5.8       Generic
Patch   October 2001
You have new mail.
# bash
bash-2.03#
/usr/platform/sun4u/sbin/prtdiag -v
System Configuration:  Sun Microsystems
sun4u Sun Enterprise 420R (4 X UltraSPA
RC-II 450MHz)
System clock frequency:
113 MHz
Memory size: 4096 Megabytes
========================= CPUs
=========================
                    Run   Ecache   CPU    CPU
Brd
CPU   Module   MHz     MB    Impl.   Mask
---  ---  -------  -----  ------
------  ----
 0     0     0      450     4.0   US-II    10.0
 0     1     1
450     4.0   US-II    10.0
 0     2     2      450     4.0   US-II    10.0
 0
3     3      450     4.0   US-II    10.0
========================= IO Cards
=========================
     Bus   Freq
Brd  Type  MHz   Slot        Name
Model
---  ----  ----  ----------  --------------------------------
-----------------
-----
 0   PCI    33     On-Board  network-SUNW,hme
 0
PCI    33     On-Board  scsi-glm/disk (block)             Symbios,53C875
 0
PCI    33     On-Board  scsi-glm/disk (block)             Symbios,53C875
 0
PCI    33   pcib slot 4  scsi-glm/disk (block)             Symbios,53C875
 0
PCI    33   pcib slot 4  scsi-glm/disk (block)             Symbios,53C875
 0
PCI    33   pcia slot 1  pci-pci1011,25.4/pci108e,1000     pci-bridge
 0
PCI    33   pcia slot 1  SUNW,qfe-pci108e,1001             SUNW,pci-qfe
 0
PCI    33   pcia slot 1  SUNW,qfe-pci108e,1001             SUNW,pci-qfe
 0
PCI    33   pcia slot 1  SUNW,qfe-pci108e,1001             SUNW,pci-qfe
 0
PCI    33   pcia slot 1  SUNW,qfe-pci108e,1001             SUNW,pci-qfe
No
failures found in System
===========================
========================= HW Revisions =========================
ASIC
Revisions:
---------------
PCI: pci Rev 4
PCI: pci Rev 4
Cheerio: ebus Rev 1
System PROM revisions:
----------------------
  OBP 3.29.0 2000/12/20 18:40
POST 1.2.8 2000/08/22 19:50
bash-2.03#
Regards,
Manoj Ghag
_______________________________________________
sunmanagers mailing list
sunmanagers@sunmanagers.org
http://www.sunmanagers.org/mailman/listinfo/sunmanagers


This archive was generated by hypermail 2.1.7 : Wed Apr 09 2008 - 23:28:38 EDT