getting an ok prompt on a netra t4

From: VEGH Karoly (karoly.vegh@uta.at)
Date: Tue Apr 13 2004 - 09:56:43 EDT


Hi,

I'm having an issue with a netra t4, I cannot get to an 'ok' prompt
on it.

No VGA is in it, so I attached two serial-connections to it, one
to the LOM card, and one to the port 'A'.

the lom-port is full functional, but on port 'A' I can't get an 'ok'
prompt.

Both cables are OK, tested.

lom>show
escape #.
model Netra T4
hostname cl201
power-on-decline off
power-on-delay off
bootmode normal
rsc-security off
flow-control off
login-timeout off
event-reporting on
Time since last boot: +96d+20h17m43s
lom>

there is a 'console' command in the lom> commandline-prompt, but I don't know
the right syntax to use it.

how to set the default console-output to port 'A'?

on port 'A' I get no information at, all, though it worked, before I begun
to install the box (and stopped it to begin again) with 'boot net'.

I would need to start with 'boot net' again, but cannot start it without
an ok prompt.

any ideas?

any help is appreciated

tia

charlie

-- 
Vigh Karoly -  System Engineer - UTA - TIS.SAS.BSS
"There are two major products that come out of Berkeley: LSD and UNIX.
 We don't believe this to be a coincidence." 
 				- Jeremy S. Anderson
_______________________________________________
sunmanagers mailing list
sunmanagers@sunmanagers.org
http://www.sunmanagers.org/mailman/listinfo/sunmanagers


This archive was generated by hypermail 2.1.7 : Wed Apr 09 2008 - 23:28:27 EDT