From: Lauri Bettencourt (lbetten@ziplink.net)
Date: Mon Mar 29 2004 - 13:39:12 EST
Hi:
I have a two Netra t4 units that came in from the field and neither will
poweron past the lom prompt.
Below is the information I can get from the system. Anyone else ever
experience this?
lom>help
The following commands are supported:
alarmon
alarmoff
check
console
environment
faulton
faultoff
help
poweron
poweroff
reset
show
version
lom>show
model Netra t140x
hostname cl205
eventlog
host reset
power off
PSU 3 Input failed
PSU 2 Input failed
PSU 1 Input failed
PSU 1 Input failed
PSU 2 Input failed
PSU 2 OK
PSU 1 OK
power on
first fatal error
-
lom>ver
LOM version: 2.2
LOM checksum: C9B2
LOM firmware build Oct 20 1999 13:34:25
lom>environment
Fault OFF
Alarm1 OFF
Alarm2 OFF
Alarm3 ON
Fans:
1 OK speed 62%
2 OK speed 62%
3 OK speed 60%
4 OK speed 60%
PSUs:
1 OK
2 OK
3 OK
Thanks,
Lauri-
_______________________________________________
sunmanagers mailing list
sunmanagers@sunmanagers.org
http://www.sunmanagers.org/mailman/listinfo/sunmanagers
This archive was generated by hypermail 2.1.7 : Wed Apr 09 2008 - 23:28:22 EDT