Netra t4 not powering on from lom prompt

From: Lauri Bettencourt (lbetten@ziplink.net)
Date: Mon Mar 29 2004 - 13:39:12 EST


Hi:

I have a two Netra t4 units that came in from the field and neither will
poweron past the lom prompt.
Below is the information I can get from the system. Anyone else ever
experience this?

lom>help
The following commands are supported:

alarmon
alarmoff
check
console
environment
faulton
faultoff
help
poweron
poweroff
reset
show
version

lom>show
model Netra t140x
hostname cl205
eventlog
   host reset
   power off
   PSU 3 Input failed
   PSU 2 Input failed
   PSU 1 Input failed
   PSU 1 Input failed
   PSU 2 Input failed
   PSU 2 OK
   PSU 1 OK
   power on
  first fatal error
    -

lom>ver
LOM version: 2.2
LOM checksum: C9B2
LOM firmware build Oct 20 1999 13:34:25

lom>environment
Fault OFF
Alarm1 OFF
Alarm2 OFF
Alarm3 ON

Fans:
1 OK speed 62%
2 OK speed 62%
3 OK speed 60%
4 OK speed 60%

PSUs:
1 OK
2 OK
3 OK

Thanks,

Lauri-