SUMMARY: e250 Memory errors

From: Kevin A. Sindhu (kevin.a.sindhu@Mail.AC)
Date: Thu Feb 05 2004 - 23:14:51 EST


Thanks to Jay Lessert <jay_lessert@accelerant.net> for his quick reply:

-------
>> Hi All,
>>
>> I'm having problems booting a e250 and don't quite know which one is
>> the suspect. We've tried to replace the memory, reset both CPU/Memory
>> but still have these problems...I looked around on sunsolve but couldn't
>> find anything. I'll appreciate if someone can guide me on what's going:

>> 0> <00> Probe Memory
>> 0>WARNING: SIMM Failure detected in Bank 0
>> 0> SIMM U0701 = 128MB.
>> 0> SIMM U0801 = 128MB.
>> 0> SIMM U0901 = 0MB.
>> 0> SIMM U1001 = 0MB.

You can't do that! E250 has four banks of four. It looks like you
have one half-populated bank.

If you have no documentation for this box, go to:

     http://sunsolve.sun.com/handbook_pub/

and download it.

-------

I can't believe I didn't remember that! Problem fixed. Thanks a bunch guyz

-Kevin
_______________________________________________
sunmanagers mailing list
sunmanagers@sunmanagers.org
http://www.sunmanagers.org/mailman/listinfo/sunmanagers



This archive was generated by hypermail 2.1.7 : Wed Apr 09 2008 - 23:27:59 EDT