I have a disk in a 5200 array that is getting me to scratch my head a little.
Its under VxVM controle.
Here is some output to start off with:
>vxdisk list
DEVICE TYPE DISK GROUP STATUS
c0t0d0s2 sliced rootdisk rootdg online
c0t1d0s2 sliced rootmirror rootdg online nohotuse
.
.
.
c1t34d0s2 sliced - - online
c1t35d0s2 sliced oracled04 oracledg online nohotuse
.
.
.
- - oracled03 oracledg failed failing was:c1t34d0s2
>vxprint -thA oracled03 (name of the disk in question)
Disk group: oracledg
DM NAME DEVICE TYPE PRIVLEN PUBLEN STATE
dm oracled03 - - - - NODEVICE
my messages logs have no errors in them.
thanks
nicholas
_______________________________________________
sunmanagers mailing list
sunmanagers@sunmanagers.org
http://www.sunmanagers.org/mailman/listinfo/sunmanagers