From: Michael Blancas (mblancas@mozcom.com)
Date: Tue May 27 2003 - 08:19:00 EDT
I have a Sun E250 attached to an A1000 with two LUNs, LUN0 is a 4 disk
raid5 and LUN1 is a 3 disk raid5. I have deleted LUN1 and configured one
drive as a hot spare. I also have removed the rest of the
unassigned/unused drives. Problem is the drives I removed are still
shown by drivutil as failed drives. How could I remove the drives from
the listing without a reboot or resetting the configuration of the
A1000. We are running our RADIUS and LDAP on this server on LUN0, so a
reset configuration is out of the question. Any help would be appreciated.
aaa:/usr/lib/osa/bin# ./drivutil -i c1t5d0s0
Drive Information for ed017_002
Location Capacity Status Vendor Product Firmware
Serial
(MB) ID Version
Number
[1,0] 17274 Optimal FUJITSU MAG3182L SUN18G 1111
00525039
[2,0] 17274 Optimal FUJITSU MAG3182L SUN18G 1111
00525395
[1,1] 17274 Optimal FUJITSU MAG3182L SUN18G 1111
00525121
[2,1] 17274 Optimal FUJITSU MAG3182L SUN18G 1111
00525027
[1,2] 17366 Spare-Stdby SEAGATE ST318275LC 0001
3AK0BTC100
[2,2] 0 Failed
[1,3] 0 Failed
[2,3] 0 Failed