[HPADM] [SUMMARY] Binary Compatibility when moving from PA-RISC to Itanium

From: Javier Gonzalez (jgonzalez@conatel.com.uy)
Date: Thu May 20 2004 - 13:53:05 EDT


Hello and thanks to all who have replied.

It should be a great deal of binary compatibility between code running on RISC/HP-UX 11i or 11.00 and Itanium/HP-UX 11i v2.

Itanium comes with a tool called Aries which makes dynamic code translation for running RISC code untouched. ( a slice of peformance is lost consequently ).

Recompile source code and optimize would be a better option if applicable.

I've told that problems could arise with PA-RISC executables that had shared libraries statically linked.

No problems with data porting.

The ones interesting in the RISC-to-Itanium topic should follow the next links which include lots of information:

http://devresource.hp.com/drc/STK/PA_Integrity.jsp

http://h71033.www7.hp.com/isvreseller/isvreseller.asp

Best regards,

javier

--