[HPADM] RE: Question regarding V-class systems

From: STOKER, KARISSA M (SBCSI) (kw839a@sbc.com)
Date: Tue Jan 28 2003 - 09:58:26 EST


Hi,

Our system is now coming up in the correct duplex. The problem was that we
had the wrong file configured (needed to be /etc/rc.config.d/hpsppci100conf
and we needed to set the variables in the following way:

HP_SPPCI100_INTERFACE_NAME[0]=lan0
HP_SPPCI100_STATION_ADDRESS[0]=
HP_SPPCI100_SPEED[0]=100FD

Thank you so much to the following people for your help: Mike Pappenheim,
Thomas Leber, Richard Goodwin, Ryan, Richard Wright, HGreen, Bill Hassell,
Wesley Hoeflinger, Kevin Davisson, Steve Illgen.

Karissa Stoker
SBC Services, Inc.
* Karissa.Stoker@sbc.com
Phone: 214-576-5505

--
             ---> Please post QUESTIONS and SUMMARIES only!! <---
        To subscribe/unsubscribe to this list, contact majordomo@dutchworks.nl
       Name: hpux-admin@dutchworks.nl     Owner: owner-hpux-admin@dutchworks.nl
 
 Archives:  ftp.dutchworks.nl:/pub/digests/hpux-admin       (FTP, browse only)
            http://www.dutchworks.nl/htbin/hpsysadmin   (Web, browse & search)


This archive was generated by hypermail 2.1.7 : Sat Apr 12 2008 - 11:02:25 EDT