Antwort: Re: Antwort: Re: Antwort: Re: SP nodes hangs during migration on LED c48 [Virus checked]

From: fmu@OERAG.DE
Date: Wed Mar 10 2004 - 05:44:05 EST


Hi *,

I find the problem. It was an entrie in the blv.
I started the migration already once without success. So I go back (change
bootpresponse to disk and boot the node, was o.k. and on AIX 4.3.3), but
the following command r blv says it is on level 5.2:
/usr/lpp/bosinst/blvset -d /dev/hdisk0 -g level

So I change this with the same command but with the option -p to 4.3

Now I start the migration again and It doesn't stop with c48

Best regards,
Frank Mueller

                      "Green, Simon"
                      <Simon.Green@EU.A An: aix-l@Princeton.EDU
                      LTRIA.COM> Kopie:
                      Gesendet von: IBM Thema: Re: Antwort: Re: Antwort: Re: SP nodes hangs during migration on LED c48
                      AIX Discussion [Virus checked]
                      List
                      <aix-l@Princeton.
                      EDU>

                      10.03.2004 10:43
                      Bitte antworten
                      an IBM AIX
                      Discussion List

The fastest way to figure out what the problem is, is via the s1term: see
what it's prompting for. Otherwise you just end up running lots of
nodeconds until you finally hit on the problem.

However...
Did you re-set the bootlist after you unmirrored rootvg? What disks was
hd5
on?

Generally, IBM advice using the hardware address for rootvg disks in the
SDR. You might try changing it to use these, just in case.

--
Simon Green
Altria ITSC Europe Ltd
AIX-L Archive at https://new-lists.princeton.edu/listserv/aix-l.html
New to AIX? http://publib-b.boulder.ibm.com/redbooks.nsf/portals/UNIX
N.B. Unsolicited email from vendors will not be appreciated.
Please post all follow-ups to the list.
> -----Original Message-----
> From: fmu@OERAG.DE [mailto:fmu@OERAG.DE]
> Sent: 10 March 2004 08:44
> To: aix-l@Princeton.EDU
> Subject: Antwort: Re: Antwort: Re: SP nodes hangs during
> migration on LED c48 [Virus checked]
>
>
> yes. But it is not normal that the node needs an input by a
> migration. It
> must be an configuration problem on node or/and SDR
>
 > I think so......


This archive was generated by hypermail 2.1.7 : Wed Apr 09 2008 - 22:17:41 EDT