Re: Microcode / Firmware Upgrades on 9076-270 SP Node

From: Green, Simon (Simon.Green@EU.ALTRIA.COM)
Date: Wed Nov 12 2003 - 06:07:20 EST


> From: Williamson, Alan
>
> I need to upgrade the firmware on all of our SP nodes.
> ( 9076-270 wide nodes ), and I have a few questions.

> 1) Do you guys always do these upgrades yourselves or do
> you use IBM engineers?

I do them myself.

> 2) Do you have spare service processor cards etc.

No. I've never experienced a problem during a firmware update.

> 3) Are there any Gotchas I should be aware of?

Just be careful. I always make sure to check the instructions
each time I download and install a new level: I have seen them
change between levels and of course they're different between
models, so it's dangerous to rely on your memory, or an old
document. The up-to-date instructions will also include
check-sum information.

We've been doing a lot of firmware upgrades recently: Silver and
WinterhawkII nodes, plus M80/6M1 and 6H1 SP Attached servers.

We did have a problem with the 6H1 code: following an upgrade to
CM_MM_030829 migration from 4.3.3 to 5.1 failed, so we've stuck
with 021213.

I haven't had any other problems, though.

Simon Green
Altria ITSC Europe Ltd

AIX-L Archive at https://new-lists.princeton.edu/listserv/aix-l.html

AIX FAQ at http://www.faqs.org/faqs/aix-faq/

N.B. Unsolicited email from vendors will not be appreciated.
Please post all follow-ups to the list.



This archive was generated by hypermail 2.1.7 : Wed Apr 09 2008 - 22:17:20 EDT