From: fmu@OERAG.DE
Date: Mon Mar 17 2003 - 11:53:12 EST
Hi *,
I want to configure a p630 over HMC on our SP. We have 1 x SP-frame
8nodes), no SP-switch, attached 2 x 6H1 (Frame 2,3) and now a p630 over
HMC.
cws is on AIX 5.1_ML03 and PSSP 3.5 latest ptfset.
The spmon command with option -G find the new frame and the new node. But
the spmon without the -G option not.
Additional find the splstdata -f the new frame but the splstdata -n no new
node.
Have I a problem with partions? And what is the reason, that the SDR shows
no new node?
#spmon -G -d
1. Checking server process
Process 26198 has accumulated 0 minutes and 6 seconds.
Check successful
2. Opening connection to server
Connection opened
Check successful
3. Querying frame(s)
4 frames
Check successful
4. Checking frames
Controller Slot 17 Switch Switch Power supplies
Frame Responds Switch Power Clocking A B C D
----- ---------- ------- ------ -------- ----- ----- ----- -----
1 yes no N/A N/A on on on on
2 yes no N/A N/A N/A N/A N/A N/A
3 yes no N/A N/A N/A N/A N/A N/A
4 yes no N/A N/A N/A N/A N/A N/A
5. Checking nodes
----------------------------------- Frame 1
----------------------------------
Host Switch Key Env Front Panel
LCD/LED
Slot Node Type Power Responds Responds Switch Error LCD/LED
Flashes
---- ---- ----- ----- -------- -------- ------- ----- ----------------
-------
1 1 wide on yes noconn normal no LEDs are blank
no
3 3 wide on yes noconn N/A no LCDs are blank
no
5 5 thin on yes noconn normal no LEDs are blank
no
6 6 thin on yes noconn normal no LEDs are blank
no
7 7 wide on yes noconn N/A no LCDs are blank
no
9 9 wide on yes noconn N/A no LCDs are blank
no
13 13 wide on yes noconn N/A no LCDs are blank
no
15 15 wide on yes noconn N/A no LCDs are blank
no
----------------------------------- Frame 2
----------------------------------
Host Switch Key Env Front Panel
LCD/LED
Slot Node Type Power Responds Responds Switch Error LCD/LED
Flashes
---- ---- ----- ----- -------- -------- ------- ----- ----------------
-------
1 17 extrn on yes noconn N/A N/A LCDs are blank
no
----------------------------------- Frame 3
----------------------------------
Host Switch Key Env Front Panel
LCD/LED
Slot Node Type Power Responds Responds Switch Error LCD/LED
Flashes
---- ---- ----- ----- -------- -------- ------- ----- ----------------
-------
1 33 extrn on yes noconn N/A N/A LCDs are blank
no
----------------------------------- Frame 4
----------------------------------
Host Switch Key Env Front Panel
LCD/LED
Slot Node Type Power Responds Responds Switch Error LCD/LED
Flashes
---- ---- ----- ----- -------- -------- ------- ----- ----------------
-------
1 49 thin on ERR ERR N/A N/A LCDs are blank
N/A
(root:hermes_e)[/]
# splstdata -n
List Node Configuration Information
node# frame# slot# slots initial_hostname reliable_hostname dce_hostname
default_route processor_type processors_installed description
on_switch LPAR_name
----- ------ ----- ----- ----------------- -----------------
----------------- --------------- -------------- --------------------
--------------- --------- ----------
1 1 1 2 charon charon_e ""
100.100.1.5 UP 1 135_MHz_P2SC_Wi
0 ""
3 1 3 2 pegasus pegasus_e ""
100.100.1.5 MP 4 332_MHz_SMP_Wid
0 ""
5 1 5 1 apollon apollon_e ""
100.100.1.5 UP 1 120_MHz_P2SC_Th
0 ""
6 1 6 1 styx styx_e ""
100.100.1.5 UP 1 120_MHz_P2SC_Th
0 ""
7 1 7 2 argus argus_e ""
100.100.1.5 MP 2 375/450_MHz_POW
0 ""
9 1 9 2 zeus zeus_e ""
100.100.1.5 MP 2 375/450_MHz_POW
0 ""
13 1 13 2 ikarus ikarus_e ""
100.100.1.5 MP 2 332_MHz_SMP_Wid
0 ""
15 1 15 2 medusa medusa_e ""
100.100.1.5 MP 2 332_MHz_SMP_Wid
0 ""
17 2 1 1 helios helios_e ""
100.100.1.5 MP 2 7026-6H1
0 ""
33 3 1 1 phoenix phoenix_e ""
100.100.1.5 MP 2 7026-6H1
0 ""
(root:hermes_e)[/]
# splstdata -f
List Frame Database Information
frame# tty s1_tty frame_type hardware_protocol
control_ipaddrs domain_name
------ ---------------- ---------------- --------------- ------------------
--------------- -----------
1 /dev/tty1 "" noswitch SP
"" ""
2 /dev/tty2 "" "" CSP
"" ""
3 /dev/tty3 "" "" CSP
"" ""
4 "" "" "" HMC
100.100.1.20 Castor
# splstdata -p
List System Partition Information
System Partitions:
------------------
hermes_e
Syspar: hermes_e
-------------------------------------------------------------------------------
syspar_name hermes_e
ip_address 100.100.1.5
install_image default
syspar_dir ""
code_version PSSP-3.2
haem_cdb_version 1047914467,456888731,0
auth_install k4
auth_root_rcmd k4
auth_methods k4:std
ts_auth_methods compat
Best regards,
Frank Müller