p630 over HMC on SP

From: fmu@OERAG.DE
Date: Mon Mar 17 2003 - 11:53:12 EST


Hi *,
      I want to configure a p630 over HMC on our SP. We have 1 x SP-frame
8nodes), no SP-switch, attached 2 x 6H1 (Frame 2,3) and now a p630 over
HMC.
cws is on AIX 5.1_ML03 and PSSP 3.5 latest ptfset.

The spmon command with option -G find the new frame and the new node. But
the spmon without the -G option not.
Additional find the splstdata -f the new frame but the splstdata -n no new
node.

Have I a problem with partions? And what is the reason, that the SDR shows
no new node?

#spmon -G -d

1. Checking server process
    Process 26198 has accumulated 0 minutes and 6 seconds.
    Check successful

2. Opening connection to server
    Connection opened
    Check successful

3. Querying frame(s)
    4 frames
    Check successful

4. Checking frames

      Controller Slot 17 Switch Switch Power supplies
Frame Responds Switch Power Clocking A B C D
----- ---------- ------- ------ -------- ----- ----- ----- -----
   1 yes no N/A N/A on on on on
   2 yes no N/A N/A N/A N/A N/A N/A
   3 yes no N/A N/A N/A N/A N/A N/A
   4 yes no N/A N/A N/A N/A N/A N/A

5. Checking nodes
----------------------------------- Frame 1
----------------------------------
                      Host Switch Key Env Front Panel
LCD/LED
Slot Node Type Power Responds Responds Switch Error LCD/LED
Flashes
---- ---- ----- ----- -------- -------- ------- ----- ----------------
-------
  1 1 wide on yes noconn normal no LEDs are blank
no
  3 3 wide on yes noconn N/A no LCDs are blank
no
  5 5 thin on yes noconn normal no LEDs are blank
no
  6 6 thin on yes noconn normal no LEDs are blank
no
  7 7 wide on yes noconn N/A no LCDs are blank
no
  9 9 wide on yes noconn N/A no LCDs are blank
no
 13 13 wide on yes noconn N/A no LCDs are blank
no
 15 15 wide on yes noconn N/A no LCDs are blank
no

----------------------------------- Frame 2
----------------------------------
                      Host Switch Key Env Front Panel
LCD/LED
Slot Node Type Power Responds Responds Switch Error LCD/LED
Flashes
---- ---- ----- ----- -------- -------- ------- ----- ----------------
-------
  1 17 extrn on yes noconn N/A N/A LCDs are blank
no

----------------------------------- Frame 3
----------------------------------
                      Host Switch Key Env Front Panel
LCD/LED
Slot Node Type Power Responds Responds Switch Error LCD/LED
Flashes
---- ---- ----- ----- -------- -------- ------- ----- ----------------
-------
  1 33 extrn on yes noconn N/A N/A LCDs are blank
no

----------------------------------- Frame 4
----------------------------------
                      Host Switch Key Env Front Panel
LCD/LED
Slot Node Type Power Responds Responds Switch Error LCD/LED
Flashes
---- ---- ----- ----- -------- -------- ------- ----- ----------------
-------
  1 49 thin on ERR ERR N/A N/A LCDs are blank
N/A
(root:hermes_e)[/]

# splstdata -n
                  List Node Configuration Information

node# frame# slot# slots initial_hostname reliable_hostname dce_hostname
default_route processor_type processors_installed description
on_switch LPAR_name
----- ------ ----- ----- ----------------- -----------------
----------------- --------------- -------------- --------------------
--------------- --------- ----------
    1 1 1 2 charon charon_e ""
100.100.1.5 UP 1 135_MHz_P2SC_Wi
0 ""
    3 1 3 2 pegasus pegasus_e ""
100.100.1.5 MP 4 332_MHz_SMP_Wid
0 ""
    5 1 5 1 apollon apollon_e ""
100.100.1.5 UP 1 120_MHz_P2SC_Th
0 ""
    6 1 6 1 styx styx_e ""
100.100.1.5 UP 1 120_MHz_P2SC_Th
0 ""
    7 1 7 2 argus argus_e ""
100.100.1.5 MP 2 375/450_MHz_POW
0 ""
    9 1 9 2 zeus zeus_e ""
100.100.1.5 MP 2 375/450_MHz_POW
0 ""
   13 1 13 2 ikarus ikarus_e ""
100.100.1.5 MP 2 332_MHz_SMP_Wid
0 ""
   15 1 15 2 medusa medusa_e ""
100.100.1.5 MP 2 332_MHz_SMP_Wid
0 ""
   17 2 1 1 helios helios_e ""
100.100.1.5 MP 2 7026-6H1
0 ""
   33 3 1 1 phoenix phoenix_e ""
100.100.1.5 MP 2 7026-6H1
0 ""
(root:hermes_e)[/]

# splstdata -f
                  List Frame Database Information

frame# tty s1_tty frame_type hardware_protocol
control_ipaddrs domain_name
------ ---------------- ---------------- --------------- ------------------
--------------- -----------
     1 /dev/tty1 "" noswitch SP
"" ""
     2 /dev/tty2 "" "" CSP
"" ""
     3 /dev/tty3 "" "" CSP
"" ""
     4 "" "" "" HMC
100.100.1.20 Castor

# splstdata -p
List System Partition Information

System Partitions:
------------------
hermes_e

Syspar: hermes_e
-------------------------------------------------------------------------------
syspar_name hermes_e
ip_address 100.100.1.5
install_image default
syspar_dir ""
code_version PSSP-3.2
haem_cdb_version 1047914467,456888731,0
auth_install k4
auth_root_rcmd k4
auth_methods k4:std
ts_auth_methods compat

Best regards,
Frank Müller