From: Bill Verzal (Bill_Verzal@BCBSIL.COM)
Date: Wed Oct 09 2002 - 11:26:00 EDT
It is not installed by default. It is the previously referred to SDD.
BV
--------------------------------------------------------------------------------------------------------
Bill Verzal
Technical Consultant
Forbes Technical Consulting
(312) 653-3684
bill_verzal@bcbsil.com
MailStop: 27.202B
"Ignacio
Vidal" To: aix-l@Princeton.EDU
<ividal@BIYCSA cc:
.COM.AR> Subject: Re: Channel Failover
Sent by: "IBM
AIX Discussion
List"
<aix-l@Princet
on.EDU>
10/09/2002
10:45 AM
Please respond
to "IBM AIX
Discussion
List"
Hello:
A little question...
Is there any other product (similar to Powerpath from EMC) that allows load
balancing and automatic failover for FC host adapters? (is it included in
AIX 5.x?)
Thank you
Ignacio
> -----Mensaje original-----
> De: Bill Verzal [mailto:Bill_Verzal@BCBSIL.COM]
> Enviado el: miércoles, 09 de octubre de 2002 12:00
> Para: aix-l@Princeton.EDU
> Asunto: Re: Channel Failover
>
>
>
> EMC's product is called Powerpath
> --------------------------------------------------------------
> ------------------------------------------
>
> Bill Verzal
> Technical Consultant
> Forbes Technical Consulting
> (312) 653-3684
> bill_verzal@bcbsil.com
> MailStop: 27.202B
>
>
>
> "Saxon, Lamar"
> <Lamar.Saxon@AMERIC To:
> aix-l@Princeton.EDU
> REDIT.COM> cc:
> Sent by: "IBM AIX Subject:
> Re: Channel Failover
> Discussion List"
> <aix-l@Princeton.ED
> U>
>
>
> 10/09/2002 09:45 AM
> Please respond to
> "IBM AIX Discussion
> List"
>
>
>
>
>
>
> I thought that was a function of the device drive software.
> AIX 4.3.3 with
> ESS and SDD ( sub system device driver ) supports failover & load
> balancing. I would think EMC had a similar product.
>
> Lamar
> -----Original Message-----
> From: Ganeshan_Bala@EMC.COM [mailto:Ganeshan_Bala@EMC.COM]
> Sent: Wednesday, October 09, 2002 9:25 AM
> To: aix-l@Princeton.EDU
> Subject: Channel Failover
>
> Hello,
>
> Does AIX 5L LVM provide channel fail over capabilities
> between HBA's.
> I know it was not available in AIX 4x but I am not sure
> about 5. Any
> pointers are appreciated. Thanks.
>
> Bala
>
> ----------------------------------------------
> Bala Ganeshan
> Technical Architect
> 2850 Premiere Parkway
> Duluth, GA 30097
>
> Phone: (770) 814-3667
> Cell: (678) 463-5741
> email: ganeshan_bala@emc.com
> (Embedded image moved to file: pic23280.gif)
> ----------------------------------------------
>
>
>
>
This archive was generated by hypermail 2.1.7 : Wed Apr 09 2008 - 22:16:15 EDT