Re: 7013-570 fails to boot with led 555

From: Adams Kevin J (kevin.adams@PHS.COM)
Date: Mon Sep 09 2002 - 20:41:55 EDT


Your right. It just happened so quick in the boot I thought it was hardware.

I'm now following the standard AIX 555 trouble shooting steps.

Thanks,
kevin

-----Original Message-----
From: Steve Chandler [mailto:schandler@APPLE.COM]
Sent: Monday, September 09, 2002 5:22 PM
To: aix-l@Princeton.EDU
Subject: Re: [aix-l] 7013-570 fails to boot with led 555

You can the "Diagnostic information for Microchannel bus systems" on the IBM
web site at

http://www-1.ibm.com/servers/eserver/pseries/library/hardware_docs/a4a/a4af5
bas.pdf
<http://www-1.ibm.com/servers/eserver/pseries/library/hardware_docs/a4a/a4af
5bas.pdf>

LED 555 is not specific to a RS/6000 570

According to the manual (page 23-6) this error is:

555 An ODM error occurred when trying to varyon the rootvg, or unable to
create an
NFS swap device during network boot.

steve

Adams Kevin J wrote:

Dear very old equipment owners:

I get led 555 real early in the boot on a 7013-570 and it just hangs.

Don't have the books nor does the IBM websites, at least not that I could
find.

This happened after a power outage and no ups.

Thanks,
Kevin

This electronic message transmission, including any attachments, contains
information from PacifiCare Health Systems Inc. which may be confidential or
privileged. The information is intended to be for the use of the individual
or entity named above. If you are not the intended recipient, be aware that
any disclosure, copying, distribution or use of the contents of this
information is prohibited.

If you have received this electronic transmission in error, please notify
the sender immediately by a "reply to sender only" message and destroy all
electronic and hard copies of the communication, including attachments.

--
Steve Chandler - Apple Computer
520 744 0410 (Office)
520 907 3969 (mobile)
866 728 2421 (fax)
This electronic message transmission, including any attachments, contains information from PacifiCare Health Systems Inc. which may be confidential or privileged. The information is intended to be for the use of the individual or entity named above. If you are not the intended recipient, be aware that any disclosure, copying, distribution or use of the contents of this information is prohibited.
If you have received this electronic transmission in error, please notify the sender immediately by a "reply to sender only" message and destroy all electronic and hard copies of the communication, including attachments.


This archive was generated by hypermail 2.1.7 : Wed Apr 09 2008 - 22:16:11 EDT