Re: recovering from lost hdiskpower devices

From: Bob.Kelley@BRINKSINC.COM
Date: Fri May 14 2004 - 10:43:16 EDT


Thanks Patrick, I came in this morning only to find my two fc paths dead.
Even after stopping/starting the agent, powermt config, and rebooting, they
only come back alive for about 10 minutes, then they go dead?

Bobby Kelley Jr.
972-877-5341

|---------+---------------------------->
| | "Patrick B. |
| | O'Brien" |
| | <pobrien@DOIT.NV.|
| | GOV> |
| | Sent by: IBM AIX |
| | Discussion List |
| | <aix-l@Princeton.|
| | EDU> |
| | |
| | |
| | 05/13/2004 05:16 |
| | PM |
| | Please respond to|
| | IBM AIX |
| | Discussion List |
| | |
|---------+---------------------------->
>---------------------------------------------------------------------------------------------------------------------------------------------|
  | |
  | To: aix-l@Princeton.EDU |
  | cc: |
  | Subject: Re: recovering from lost hdiskpower devices |
>---------------------------------------------------------------------------------------------------------------------------------------------|

I would do a;

chdev -l hdiskpower0 -a pv=clear,
chdev -l hdiskpower0 -a pv=yes, to reinit your pvid, then
recreatevg -y vg_name hdiskpowername.

I just had to do this, this morning. This command will do importvg and a
varyonvg too.

-----Original Message-----
From: Bob.Kelley@BRINKSINC.COM [mailto:Bob.Kelley@BRINKSINC.COM]
Sent: Thursday, May 13, 2004 3:10 PM
To: aix-l@Princeton.EDU
Subject: recovering from lost hdiskpower devices

Anybody seen anything similiar to this or have any insight? Help much
appreciated on this!

After a 5.1->5.2 upgrade, I found that I cannot import the volume group
which resides on a CX600 LUN. I have flashed the fcX adapters with the
latest microcode, andh here are the EMC software versions:
PowerPath 3.0.4.0
NaviAgent 6.2.0.6
CLArray 5.2.0.7

This is the error I'm getting:
[root@nad0019aixd05/home/root]# importvg -y oraclevg hdiskpower0
0516-024 lqueryvg: Unable to open physical volume.
        Either PV was not configured or could not be opened. Run
        diagnostics.
0516-024 lqueryvg: Unable to open physical volume.
        Either PV was not configured or could not be opened. Run
        diagnostics.
0516-1140 importvg: Unable to read the volume group descriptor area
        on specified physical volume.

powermt display dev=all shows this:
Pseudo name=hdiskpower0
CLARiiON ID=APM00023800314
Logical device ID=600601F86D0A00007A865AF0B555D711
state=alive; policy=CLAROpt; priority=0; queued-IOs=0
Owner: default=SP A, current=SP B
==============================================================================

---------------- Host --------------- - Stor - -- I/O Path - -- Stats

---
### HW Path                 I/O Paths    Interf.   Mode    State  Q-IOs
Errors
==============================================================================
  0 fscsi0                    hdisk3     SP A3     active  alive      0
0
  1 fscsi1                    hdisk5     SP B3     active  alive      0
0
I also noticed something peculiar, I have the LUNZ devices showing up now:
hdisk0      Available 10-60-00-10,0 16 Bit LVD SCSI Disk Drive
hdisk1      Available 10-60-00-11,0 16 Bit LVD SCSI Disk Drive
hdisk2      Available 20-58-01      FC CLArray LUNZ Disk
hdisk3      Available 20-58-01      FC CLArray RAID 5 Disk Group
hdisk4      Available 20-60-01      FC CLArray LUNZ Disk
hdisk5      Available 20-60-01      FC CLArray RAID 5 Disk Group
hdiskpower0 Available 20-58-01      PowerPath Device
Bobby Kelley Jr.
972-877-5341
NOTICE TO BRINK'S EMPLOYEES:
All electronic mail communications composed, sent, received or stored on or
through Brink's equipment are subject to the Brink's Electronic
Communications Policy.  Employees should have no expectation of privacy in
their use of the Company's electronic mail system.


This archive was generated by hypermail 2.1.7 : Wed Apr 09 2008 - 22:17:55 EDT