SUMMARY: HSZ70 EMU error

From: Maglinger, Paul (PMAGLINGER@scvl.com)
Date: Wed Nov 01 2006 - 16:34:19 EST


Thanks to Joseph Senulis, John Lanier, and Guy Noce for the quick
responses.
A beer for Mike Miller whenever he's in southern Indiana for sending a
PDF with the EMU LED codes, which told me about a defective cooling fan
on the top left (facing the back of the shelf). (I'll buy John a beer
as well for sending me the HSZ70 service manuals to add to my library).

Thanks, and cheers to all.

Paul
 

Off the strict path of Tru64 software issues, but we do have it running
on a DS20 cluster with a pair of HSZ70 controllers as a development
system. One of our EMUs is sending out a long beep about every minute
and the number 5 led is lighting. I tried Googling, maybe not typing
the right thing, but can't find any troubleshooting information. Can
someone point me in the right direction?
 
Paul Maglinger, A+, CA, CCA, CET, MCSE

Systems Administrator
Shoe Carnival Inc.
(812)867-4674
pmaglinger@scvl.com

________________________________

 