SUMMARY: HSG80 Fan failure

From: Reiner Dassing (dassing@wettzell.ifag.de)
Date: Mon Sep 13 2004 - 10:49:27 EDT


Hi Managers!

My question was:

     After the command
        configuration reset
     the error
            Fan failure detected.
     still exists and the controller shuts down after some time.

I got a lot of answers very fast.
Many thanks to all who have answered especially to
Peter Reynolds, Greg Rudd and to Dr. Thomas Blinn.

They pointed me to a hardware problem by explaing the leds of EMU.

After refitting and cleaning all the electric contacts of all
fans the problem was solved.

-- 
Mit freundlichen Gruessen / With best regards
    Reiner Dassing


This archive was generated by hypermail 2.1.7 : Sat Apr 12 2008 - 10:50:08 EDT