UPDATE: HSZ22 controller,password

From: Shaun.Racine@intier.com
Date: Sat Aug 21 2004 - 09:57:40 EDT


Found the password;
DECRAID

I believe I have through every menu item, and cannot find a way to turn the
alarm off.
There is a switch on the back of the array, which does mute it, but when
switched back up it is audible again.
I do not want to leave it switched off, in case we need the audible alert
for future problems.

How can I silence the alarm with the menu?

Shaun

email: shaun.racine@intier.com
----- Forwarded by Shaun Racine/MISGroup on 21/08/2004 14:54 -----
|---------+--------------------------->
| | Shaun Racine |
| | |
| | 21/08/2004 13:03|
| | |
|---------+--------------------------->
>---------------------------------------------------------------------------------------------------------------------------------------------|
  | |
  | To: tru64 |
  | cc: |
  | Subject: HSZ22 controller,password |
>---------------------------------------------------------------------------------------------------------------------------------------------|

Hello managers,

I have a HSZ22 disk controller connected to a DS10, TRU64 v5.1 pk4

I moved this equipment between offices today, plugged one of the power
cables into the HSZ and the alarm sounded immediately. I did not
appreciate the switch was still on.

Unfortunately, plugging the other power cable in has not stopped the alarm.

The DS10 boots fine and I can see all data on the disks for the HSZ, but
have the alarm sounding continuously.

I have plugged in the serial cable to one of the controllers, it asks for a
password,, tells me its invalid and gives me just a browse screen.

I cannot imagine anyone set anything other than the default password, which
brings me to the questions.

What is the default password (for a serial terminal connection) on a HSZ22?
How can I silence the alarm?

Many thanks.
Shaun

(I am simultaneously trawling the web for the answer)



This archive was generated by hypermail 2.1.7 : Sat Apr 12 2008 - 10:50:06 EDT