HSG80 command scripter update

From: Howard Arnold (arnoldh@celerent.com)
Date: Tue May 11 2004 - 22:48:46 EDT


I have installed HSG80 Command Scripter on a 5.1a cluster connected to a
HSZ70 and the command

/usr/opt/CPQcmdscr/bin/cmdscript -f subsysdata works. So it's either 5.1b or
the HSG80 causing the problem

So does anyone have command scripter 1.0b running on 5.1b connected to
HSG80's? If so was there any special that had to be done to get it to work.

Thanks

Original question:

I have a 5.1B cluster which I have just installed Command Scripter 1.0b on
to manage my HSG80. When I issue the command
/usr/opt/CPQcmdscr/bin/cmdscript -f subsysdata it reports that No HS*
controllers are available. A hwmgr -view device -cluster shows the scp0
port. I can also do a /usr/bin/hsxterm5 -b0 -t0 -l0 "show this" and it works
fine.

I have also tried /usr/opt/CPQcmdscr/bin/cmdscript -b 0 -t 0 -l 0 show this
and I get the following:

GetDeviceInfo() failed
Communication failure

I don't have SWCC installed, but the manual implies that it can be used
without an agent.

Output of /usr/bin/hsxterm5 -b0 -t0 -l0 "show this"

Controller: HSG80 ZG10507028 Software V87S-0, Hardware E12
        NODE_ID = 5000-1FE1-0010-5B40
        ALLOCATION_CLASS = 0
        SCSI_VERSION = SCSI-3
        Not configured for dual-redundancy
        Device Port SCSI address 7
        Time: 10-MAY-2004 13:03:05
        Command Console LUN is lun 0 (IDENTIFIER = 99)
        Host Connection Table is NOT locked
        Smart Error Eject Disabled
Host PORT_1:
        Reported PORT_ID = 5000-1FE1-0010-5B43
        PORT_1_TOPOLOGY = FABRIC (fabric up)
        Address = 011000
Host PORT_2:
        Reported PORT_ID = 5000-1FE1-0010-5B44
        PORT_2_TOPOLOGY = FABRIC (fabric up)
        Address = 011100
        NOREMOTE_COPY
Cache:
        256 megabyte write cache, version 0022
        Cache is GOOD
        Unflushed data in cache
        CACHE_FLUSH_TIMER = DEFAULT (10 seconds)
Mirrored Cache:
        Not enabled
Battery: NOUPS MORE THAN 50% CHARGED
        Expires: 10-MAY-2006
hsg80t>

Thanks for any help that can be provided.

Howard Arnold
Consultant Engineer
Phone: (603) 685-6060 ext. 206
Email: arnoldh@celerent.com
www.celerent.com