Summary #2 Can I power-off a machine remotely?

From: Dr. David Kirkby (davek@medphys.ucl.ac.uk)
Date: Fri May 30 2003 - 07:01:15 EDT


Following my summary of this matter, Bob Marcan <bob.marcan@aster.si>
has some information to contradict the belief of everyone else that the
ability to power off a Dec Alpha remotely is limited to newer high spec
servers, rather than old single CPU workstations.

Although Bob's using OpenVMS, not Tru64, his email says the single
processor Dec Personal Workstation 500au can be powered off remotely.
Since the 600a I have is not too dissimilar (and is newer) than the
500au Bob's using, it seems probable the 600a might be able to do
likewise, given suitable software support.

It might be a case of the hardware is there, but there is no suitable
software in Tru64.

Here's Bob's email.

Bob Marcan wrote:

> It is definitely not true.
> PW500au, OpenVMS 7.3-1
>
> $ @sys$system:shutdown
>
> SHUTDOWN -- Perform an Orderly System Shutdown
> on node SMILJ
>
> How many minutes until final shutdown [0]:
> Reason for shutdown [Standalone]:
> Do you want to spin down the disk volumes [NO]? y
> Do you want to invoke the site-specific shutdown procedure [YES]?
> Should an automatic system reboot be performed [NO]?
> When will the system be rebooted [later]:
> Shutdown options (enter as a comma-separated list):
> REBOOT_CHECK Check existence of basic system files
> SAVE_FEEDBACK Save AUTOGEN feedback information from this boot
> DISABLE_AUTOSTART Disable autostart queues
> POWER_OFF Request console to power-off the system
>
> Shutdown options [NONE]: POWER_OFF
> SYSTEM SHUTDOWN COMPLETE
> ......
>
> halted CPU 0
>
> halt code = 5
> HALT instruction executed
> PC = ffffffff800c98c4
> >>>
>
> and machine was switched off
>
> I don't know yet how to do it on Tru64.
> Need to install Tru64 first :-)
> In a few days.
>
> Best regards, Bob
>
> --
> Bob Marcan mailto:bob.marcan@snt.si
> Aster^H^H...HermesPlus^H^H^H...S&T mailto:bob.marcan@aster.si
> Nade Ovcakove 1 tel: +386 (1) 5894-329
> 1000 Ljubljana, Slovenia http://www.snt.si

-- 
PLEASE NOTE:
If this message was sent to a newsgroup or mailing list, please 
reply to there. Personal e-mail is always welcome, but unless 
I have received e-mail from you previously, you may be sent 
an automatically generated reply, requesting that you send the
message again, adding a password in the subject line. Sorry,
but this action has been taken to prevent unsolicited 
commercial emails (spam mail). 
Dr. David Kirkby PhD,
Senior Research Fellow,
Department of Medical Physics,
University College London,
11-20 Capper St, London, WC1E 6JA.
Tel: 020 7679 6408 Fax: 020 7679 6269
Internal telephone: ext 46408
e-mail davek@medphys.ucl.ac.uk  
Web page: http://www.medphys.ucl.ac.uk/~davek


This archive was generated by hypermail 2.1.7 : Sat Apr 12 2008 - 10:49:20 EDT