SUMMARY: SMC Error while connecting to SVM through SMC enhance storage.

From: Scott Pham (spham@incellico.com)
Date: Thu Mar 13 2003 - 16:15:50 EST


        Thanks to Eric Ray [Eric.Ray@Sun.COM] for pointing out rpc.metad was not
running.

Question:

Guys,
        I'm currently having an issue with the smc console on Solaris 9, with
lastest
patches. Everything in the SMC works fine, except for the enhanced storage
tab. I'm getting error can't connect to server. Has anyone ran across this or
have a solution to this? Thanks in advance.

 This is the error from /var/adm/message
WBEM_Logging_Service[2520]: [ID 640905 daemon.notice] Service
com.sun.admin.volmgr.server.SVMServices cannot be loaded:
com.sun.management.viper.CriticalStopException: Container/Agent of service
com.sun.admin.volmgr.server.SVMServices not found.

Error from Console:

java.lang.NullPointerException
        at
com.sun.admin.volmgr.client.util.Util.serverOwnsAllDiskSets(Util.java:2456)
        at
com.sun.admin.volmgr.client.Content.checkForUnownedDiskSets(Content.java:319)
        at com.sun.admin.volmgr.client.Content$1.run(Content.java:287

Summary:

rpc.metad was not started.

"They that can give up essential liberty to obtain a little temporary safety
deserve neither liberty nor safety."
- Benjamin Franklin
_______________________________________________
sunmanagers mailing list
sunmanagers@sunmanagers.org
http://www.sunmanagers.org/mailman/listinfo/sunmanagers



This archive was generated by hypermail 2.1.7 : Wed Apr 09 2008 - 23:25:59 EDT