e3000 Flashprom trouble

From: Duross, Bill (Bill.Duross@stratus.com)
Date: Thu Feb 27 2003 - 22:28:40 EST


Hi All,

I have an E3000 that has the amber trouble light on the front of the unit
and on the clock and IO boards. I ran prtdiag and received the result
below. Does this mean that the flash prom is really toast? If it is, is
the prom itself easily replaceable or do I need to replace the entire board?
Are there redundant flash proms in an e3000?

Any advice appreciated, thanks!

# ./prtdiag -v
System Configuration: Sun Microsystems sun4u 4-slot Sun Enterprise 3000
System clock frequency: 82 MHz
Memory size: 2048Mb

========================= CPUs =========================

                    Run Ecache CPU CPU
Brd CPU Module MHz MB Impl. Mask
--- --- ------- ----- ------ ------ ----
 3 6 0 248 1.0 US-II 1.1
 3 7 1 248 1.0 US-II 1.1
 5 10 0 248 1.0 US-II 1.1
 5 11 1 248 1.0 US-II 1.1
 7 14 0 248 1.0 US-II 1.1
 7 15 1 248 1.0 US-II 1.1

========================= Memory =========================

                                              Intrlv. Intrlv.
Brd Bank MB Status Condition Speed Factor With
--- ----- ---- ------- ---------- ----- ------- -------
 3 0 1024 Active OK 60ns 2-way A
 5 0 1024 Active OK 60ns 2-way A

========================= IO Cards =========================

     Bus Freq
Brd Type MHz Slot Name Model
--- ---- ---- ---- --------------------------------
----------------------
 1 SBus 25 0 cgsix SUNW,501-2325

 1 SBus 25 1 QLGC,isp/sd (block) QLGC,ISP1000U

 1 SBus 25 2 QLGC,isp/sd (block) QLGC,ISP1000U

 1 SBus 25 3 SUNW,hme

 1 SBus 25 3 SUNW,fas/sd (block)

 1 SBus 25 13 SUNW,soc 501-2069

Failed Field Replaceable Units (FRU) in System:
==============================================
flashprom unavailable on IO Board #1
        PROM fault string: fail
        Failed Field Replaceable Unit is IO board 1

Detected System Faults
======================
PROM detected failure
        Detected Thu Jul 5 20:44:35 2001
Board 1 fault: PROM detected
Fault: fail
        Detected Thu Jul 5 20:44:35 2001

========================= Environmental Status =========================
Keyswitch position is in Normal Mode
System Power Status: Redundant
System LED Status: GREEN YELLOW GREEN
WARNING ON ON BLINKING

Fans:
-----
Unit Status
---- ------
Disk OK

System Temperatures (Celsius):
------------------------------
Brd State Current Min Max Trend
--- ------- ------- --- --- -----
 1 OK 46 35 57 stable
 3 OK 46 34 57 stable
 5 OK 48 35 59 stable
 7 OK 49 34 58 stable
CLK OK 43 32 55 stable

Power Supplies:
---------------
Supply Status
--------- ------
1 OK
3 OK
5 OK
PPS OK
    System 3.3v OK
    System 5.0v OK
    Peripheral 5.0v OK
    Peripheral 12v OK
    Auxilary 5.0v OK
    Peripheral 5.0v precharge OK
    Peripheral 12v precharge OK
    System 3.3v precharge OK
    System 5.0v precharge OK
AC Power OK

========================= HW Revisions =========================

ASIC Revisions:
---------------
Brd FHC AC SBus0 SBus1 PCI0 PCI1 FEPS Board Type Attributes
--- --- -- ----- ----- ---- ---- ---- ---------- ----------
 1 1 5 1 1 22 Dual-SBus 84MHz Capable
 3 1 5 CPU 84MHz Capable
 5 1 5 CPU 84MHz Capable
 7 1 5 CPU 84MHz Capable

System Board PROM revisions:
----------------------------
Board 1: FCODE 1.8.1 1996/12/12 18:22 iPOST 3.4.2 1997/01/10 13:34
Board 3: OBP 3.2.18 1998/09/10 14:13 POST 3.9.4 1998/06/09 16:25
Board 5: OBP 3.2.18 1998/09/10 14:13 POST 3.9.4 1998/06/09 16:25
Board 7: OBP 3.2.18 1998/09/10 14:13 POST 3.9.4 1998/06/09 16:25