prtdiag on Sun-Fire 3800 changed..

From: Ryan Larson (rlarson@foc.com)
Date: Mon Nov 25 2002 - 15:54:59 EST


With the latest patches (as of a month ago) on a Sun-Fire 3800, the output
of prtdiag changed. It no longer outputs temp or voltage info. Is there
a patch for prtdiag to fix this? Or a new OBP that might have something
to do with is?

We originally had MU6 installed and have upgraded to MU7 plus recommendeds
as of about a month ago.

Here is the old output

========================= CPUs ===============================================

            Port Run E$ CPU CPU Temp Sensor Voltage
Sensor
FRU Name ID MHz MB Impl. Mask Deg C Status Volts DC
Status
---------- ---- ---- ---- ------ ---- ----- ------ --------
------
/N0/SB2/P0 8 750 8.0 US-III 3.4 64 Green 1.73 Green
/N0/SB2/P1 9 750 8.0 US-III 3.4 63 Green 1.73 Green
/N0/SB2/P2 10 750 8.0 US-III 3.4 65 Green 1.72 Green
/N0/SB2/P3 11 750 8.0 US-III 3.4 63 Green 1.71 Green

and the new output

========================= CPUs ===============================================

            Port Run E$ CPU CPU
FRU Name ID MHz MB Impl. Mask
---------- ---- ---- ---- ------- ----
/N0/SB2/P0 8 750 8.0 US-III 3.4
/N0/SB2/P1 9 750 8.0 US-III 3.4
/N0/SB2/P2 10 750 8.0 US-III 3.4
/N0/SB2/P3 11 750 8.0 US-III 3.4

Thanks for your time
Ryan Larson
Unix Administrator
_______________________________________________
sunmanagers mailing list
sunmanagers@sunmanagers.org
http://www.sunmanagers.org/mailman/listinfo/sunmanagers



This archive was generated by hypermail 2.1.7 : Wed Apr 09 2008 - 23:25:21 EDT