From: Luisa Jorge (luisa.jorge@nexinet.pt)
Date: Wed Aug 28 2002 - 14:40:45 EDT
Hello again...
I forgot to say that I have mirror between LUN4s but each LUN as a RAID 0
configuration.
I have been reading documents and they say that i have to reconstruct the
LUN again...
As anyone done this? should I do metadettach in SDS before reconstruct the
LUN?
What is the correct procedure?
I will summarize...
Regards,
Luisa.
----- Original Message -----
From: "Luisa Jorge" <luisa.jorge@nexinet.pt>
To: <sunmanagers@sunmanagers.org>
Sent: Tuesday, August 27, 2002 1:39 PM
Subject: Change failed disk RM6 & SDS
>
> > Hello,
> >
> > I have this question:
> >
> > I have an E450 running solaris 2.6, whith two A1000 (with Raid 1)
mirrored
> > (using RM 6.22) - two LUNs, one per array. In SDS I got a message that
> two
> > of my partitions need maintenance. RM6 says that I have a disk failure
in
> > one of the LUNs. What is the correct procedure to change that disk...
With
> > SDS I know that I have to run metareplace... but what should I do with
> Raid
> > Manager? Should I destroy the failed LUN and build a new one? Or just
> change
> > the failed disk and run recovery guru? Doing the hot replacement doesn4t
> > need the disk format?
> >
> > I will summarize...
> >
> > Regards,
> > Luisa.
> > _______________________________________________
> > sunmanagers mailing list
> > sunmanagers@sunmanagers.org
> > http://www.sunmanagers.org/mailman/listinfo/sunmanagers
_______________________________________________
sunmanagers mailing list
sunmanagers@sunmanagers.org
http://www.sunmanagers.org/mailman/listinfo/sunmanagers
This archive was generated by hypermail 2.1.7 : Wed Apr 09 2008 - 23:24:51 EDT