Hi, I hope this is a valid post.

Attached is a snippet from some log files for a Sun Netra* Webhead that
we have offsite (2 hours drive away)

Are these errors as bad as they sound? i.e. does the disk look like it's
on the way out? This has only just come to my attention, so I can't
easily run fsck or format yet. I'll need to be physically at the data
centre in the middle of the night to minimise disruption

Many thanks

--
Darren Beale
*SunOS molly 5.7 Generic_106541-15 sun4u sparc
SUNW,UltraSPARC-IIi-cEngine
=============<snipped>
Aug  7 08:47:47 molly   Cmd (0x703c05b8) dump for Target 0 Lun 0:
Aug  7 08:47:47 molly unix: /pci@1f,0/pci@1,1/scsi@2 (glm0):
Aug  7 08:47:47 molly           cdb=[ 0xa 0x10 0x53 0x60 0x10 0x0 ]
Aug  7 08:47:47 molly unix: /pci@1f,0/pci@1,1/scsi@2 (glm0):
Aug  7 08:47:47 molly   pkt_flags=0x4000 pkt_statistics=0x60
pkt_state=0x7
Aug  7 08:47:47 molly unix: /pci@1f,0/pci@1,1/scsi@2 (glm0):
Aug  7 08:47:47 molly   pkt_scbp=0x0 cmd_flags=0x1860
Aug  7 08:47:47 molly unix: WARNING: /pci@1f,0/pci@1,1/scsi@2 (glm0):
Aug  7 08:47:47 molly   Connected command timeout for Target 0.0
Aug  7 08:47:47 molly unix: WARNING: ID[SUNWpd.glm.cmd_timeout.6017]
Aug  7 08:47:47 molly unix: WARNING: /pci@1f,0/pci@1,1/scsi@2 (glm0):
Aug  7 08:47:47 molly   Target 0 disabled wide SCSI mode
Aug  7 08:47:47 molly unix: WARNING:
ID[SUNWpd.glm.sync_wide_backoff.6012]
Aug  7 08:47:47 molly unix: WARNING: /pci@1f,0/pci@1,1/scsi@2 (glm0):
Aug  7 08:47:47 molly   Target 0 reverting to async. mode
Aug  7 08:47:47 molly unix: WARNING:
ID[SUNWpd.glm.sync_wide_backoff.6013]
Aug  7 08:47:47 molly unix: WARNING: /pci@1f,0/pci@1,1/scsi@2/sd@0,0
(sd0):
Aug  7 08:47:47 molly   SCSI transport failed: reason 'timeout':
retrying command
Aug  7 08:47:47 molly 
Aug  7 08:47:47 molly unix: WARNING: /pci@1f,0/pci@1,1/scsi@2/sd@1,0
(sd1):
Aug  7 08:47:47 molly   SCSI transport failed: reason 'reset': retrying
command
Aug  7 08:47:47 molly 
Aug  7 08:48:10 molly unix: WARNING: /pci@1f,0/pci@1,1/scsi@2/sd@0,0
(sd0):
Aug  7 08:48:10 molly   Error for Command: write                   Error
Level: Fatal
Aug  7 08:48:10 molly unix:     Requested Block:
542976                    Error Block: 542976
Aug  7 08:48:10 molly unix:     Vendor:
SEAGATE                            Serial Number: 0030T0VY34  
Aug  7 08:48:10 molly unix:     Sense Key: Not Ready
Aug  7 08:48:10 molly unix:     ASC: 0x4 (<vendor unique code 0x4>),
ASCQ: 0x1, FRU: 0x2
Aug  7 08:48:10 molly unix: WARNING: md: d11: write error on
/dev/dsk/c0t0d0s0
Aug  7 08:48:10 molly unix: WARNING: /pci@1f,0/pci@1,1/scsi@2/sd@0,0
(sd0):
Aug  7 08:48:10 molly   Error for Command: write                   Error
Level: Fatal
Aug  7 08:48:10 molly unix:     Requested Block:
1069920                   Error Block: 1069920
Aug  7 08:48:10 molly unix:     Vendor:
SEAGATE                            Serial Number: 0030T0VY34  
Aug  7 08:48:10 molly unix:     Sense Key: Not Ready
Aug  7 08:48:10 molly unix:     ASC: 0x4 (<vendor unique code 0x4>),
ASCQ: 0x1, FRU: 0x2
Aug  7 08:48:10 molly unix: WARNING: md: d11: write error on
/dev/dsk/c0t0d0s0
Aug  7 08:48:15 molly unix: WARNING: md: d11: /dev/dsk/c0t0d0s0 needs
maintenance
_______________________________________________
sunmanagers mailing list
sunmanagers@sunmanagers.org
http://www.sunmanagers.org/mailman/listinfo/sunmanagers