troubles with E280R

From: Gérard Henry (ghenry@cmi.univ-mrs.fr)
Date: Sun Feb 10 2008 - 03:02:36 EST


hello all,
i have a Sun E280R, S10U4. After applying patching using liveupgrade,
when rebooting, this message appears:
SUNW-MSG-ID: PCIEX-8000-5Y, TYPE: Fault, VER: 1, SEVERITY: Critical
EVENT-TIME: Sun Feb 10 08:38:43 MET 2008
PLATFORM: SUNW,Sun-Fire-280R, CSN: -, HOSTNAME: scrold
SOURCE: eft, REV: 1.16
EVENT-ID: 283c1849-36f9-e84e-ce90-f2b998397cfb
DESC: The transmitting device sent an invalid request.
   Refer to http://sun.com/msg/PCIEX-8000-5Y for more information.
AUTO-RESPONSE: One or more device instances may be disabled

IMPACT: Loss of services provided by the device instances associated
with this fault

REC-ACTION: Ensure that the latest drivers and patches are installed.
Otherwise schedule a repair procedure to replace the affected device(s).
  Use fmdump -v -u <EVENT_ID> to identify the devices or contact Sun for
support.

and more details:
scrold-root% fmdump -v -u 283c1849-36f9-e84e-ce90-f2b998397cfb
TIME UUID SUNW-MSG-ID
Feb 10 08:38:43.9158 283c1849-36f9-e84e-ce90-f2b998397cfb PCIEX-8000-5Y
    33% fault.io.pci.device-invreq

         Problem in:
hc://:product-id=SUNW,Sun-Fire-280R:server-id=scrold/motherboard=0/hostbridge=0/pcibus=0/pcidev=1/pcifn=1
            Affects: dev:////pci@8,600000/SUNW,hme@1,1
                FRU:
hc://:product-id=SUNW,Sun-Fire-280R:server-id=scrold/motherboard=0/hostbridge=0/pcibus=0/pcidev=1
           Location: -

    33% fault.io.pci.device-invreq

         Problem in:
hc://:product-id=SUNW,Sun-Fire-280R:server-id=scrold/motherboard=0/hostbridge=0/pcibus=0/pcidev=4/pcifn=0
            Affects: dev:////pci@8,600000/SUNW,qlc@4
                FRU: hc:///component=MB
           Location: -

    33% fault.io.pci.device-invreq

         Problem in:
hc://:product-id=SUNW,Sun-Fire-280R:server-id=scrold/motherboard=0/hostbridge=0/pcibus=0/pcidev=1/pcifn=0
            Affects: dev:////pci@8,600000/pci108e,1000@1
                FRU:
hc://:product-id=SUNW,Sun-Fire-280R:server-id=scrold/motherboard=0/hostbridge=0/pcibus=0/pcidev=1
           Location: -

It's the firt time i saw this kind of messages, because this machine was
just upgraded from S10 3/05 to S10U4 recently.
It seems that hme and my fc-al disks are concerned, isn't it?
Does it mean that this machine will become unusable if i don't replace
hardware components?

thanks in advance for help,

gerard
_______________________________________________
sunmanagers mailing list
sunmanagers@sunmanagers.org
http://www.sunmanagers.org/mailman/listinfo/sunmanagers



This archive was generated by hypermail 2.1.7 : Wed Apr 09 2008 - 23:42:46 EDT