Re: SAN/qlogic/Solaris10 Disk iSSUE

From: Joe A (spaceyjoe2020@yahoo.com)
Date: Sat Jan 26 2008 - 00:05:41 EST


Answer: Reboot the effected controller on the SAN resolved the issue

Questions: I have(had) a nexsan ataboy2x, qlogic 2342 and solaris 10 with vilume mgr running

-all strarted when I tried to installed external usb drive
-I was able to get to all /dev/md/dsk/d1-d15 on Saturday
-I was getting errors:
Jan 19 18:55:35 servo scsi: [ID 107833 kern.notice] Sense Key: Unit Attention
Jan 19 18:55:35 servo scsi: [ID 107833 kern.notice] ASC: 0x29 (power on, reset, or bus reset occurred), ASCQ: 0x0, FRU:
  Then I rebooted with enable enhanced logging with qlogic recommendation..
At one point I have i/o errors on like 4 vollme mgmt disks - but after the reboot I lost it all..

The 13 luns were missing and cannot be seen on the fiber but controller 1 seen and its 2 ports
Any ideas?

Thanks
Joe
       
---------------------------------
Looking for last minute shopping deals? Find them fast with Yahoo! Search.
_______________________________________________
sunmanagers mailing list
sunmanagers@sunmanagers.org
http://www.sunmanagers.org/mailman/listinfo/sunmanagers