From: Tom Crummey (tom@ee.ucl.ac.uk)
Date: Sun Sep 09 2007 - 16:57:54 EDT
Hello,
I've got several v240 machines with dual (supposedly) redundant power
supplies. However, if the power to one of the supplies is removed (due
to a partial power cut for instance) the whole system shuts down after a
few minutes' delay. There is a message in the logs:
> rmclomv: [ID 632913 kern.error] Input power unavailable for PSU @ PS1.
Is there any way to prevent this shut down when power is still available
on the other supply?
-- Tom. -------------------------------------------------------------------------- Tom Crummey, Systems and Network Manager, EMAIL: tom@ee.ucl.ac.uk Department of Electronic and Electrical Engineering, University College London, TEL: +44 (0)20 7679 3898 Torrington Place, FAX: +44 (0)20 7388 9325 London, UK, WC1E 7JE. -------------------------------------------------------------------------- -- This message has been scanned for viruses and dangerous content by MailScanner, and is believed to be clean. _______________________________________________ sunmanagers mailing list sunmanagers@sunmanagers.org http://www.sunmanagers.org/mailman/listinfo/sunmanagers
This archive was generated by hypermail 2.1.7 : Wed Apr 09 2008 - 23:42:18 EDT