From: Ing. Angel Alejandro Vega Soto (alejandro.vega@tecinfocon.com.mx)
Date: Mon Aug 27 2007 - 12:46:48 EDT
hello, I have a SFV880 in which the /var slice has been corrupted in
both sides of the mirror, (I have no idea why )
d26: Mirror
> Submirror 0: d6
> State: Needs maintenance
> Submirror 1: d16
> State: Needs maintenance
> Pass: 1
> Read option: roundrobin (default)
> Write option: parallel (default)
> Size: 16779312 blocks
>
> d6: Submirror of d26
> State: Needs maintenance
> Invoke: metareplace d26 c1t0d0s4 <new device>
> Size: 16779312 blocks
> Stripe 0:
> Device Start Block Dbase State Hot Spare
> c1t0d0s4 0 No Maintenance
>
> d16: Submirror of d26
> State: Needs maintenance
> Invoke: after replacing "Maintenance" components:
> metareplace d26 c1t1d0s4 <new device>
> Size: 16779312 blocks
> Stripe 0:
> Device Start Block Dbase State Hot Spare
> c1t1d0s4 0 No Last Erred
>
I need to fix this, Which is the best way to do it ? (I am a little
rusty on sds)
1.- shutdown the system
2.- boot cdrom -s
3.- fsck -y /dev/dsk/c1t0d0s4 ; fsck -y /dev/dsk/c1t1d0s4
4.- metareplace -e d6 c1t0d0s4
5.- metareplace -e d16 c1t1d0s4
, and all should be fine, right ? any thoghts are welcome.
Thanks and I will summarize !
-- Ing. Angel Alejandro Vega Soto Gerente de Servicio, Tecnologma Informatica y Consultorma una empresa de Grupo TIC _______________________________________________ sunmanagers mailing list sunmanagers@sunmanagers.org http://www.sunmanagers.org/mailman/listinfo/sunmanagers
This archive was generated by hypermail 2.1.7 : Wed Apr 09 2008 - 23:42:15 EDT