RAID disks have same serial numbers

From: Mumdziev, Marijan (marijan.mumdziev@siemens.com)
Date: Fri Aug 17 2007 - 09:18:15 EDT


Dear Managers,

the following issue deals with the Sunstoredge 3310. I have following raid
configuration on my Sun Storedge:

Ch Id Size Speed LD Status IDs Rev
----------------------------------
0 8 68.37GB 160MB ld0 ONLINE FUJITSU MAT3073N SUN72G0602 S/N 000515B03GYR

0 9 68.37GB 160MB ld0 ONLINE FUJITSU MAT3073N SUN72G 0602 S/N 000523B06CFS

0 10 68.37GB 160MB NONE USED SEAGATE ST373307LSUN72G 0707 S/N
3HZX15SE00007447

0 11 68.37GB 160MB ld0 REBUILD FUJITSU MAW3073NCSUN72G 1703 S/N 000726B0MR8L

0 12 68.37GB 160MB ld0 ONLINE FUJITSU MAT3073N SUN72G 0602 S/N 000515B03GSM

0 13 68.37GB 0MB NONE FRMT SEAGATE ST373307LSUN72G 0707 S/N 3HZX15SE00007447

As noticeable, two disks 0.10 and 0.13 have the same serial number,
therefore I assume this is some logical error. However, I would like to
resolve this issue and configure the disk as global-spare. I use sccli
version
2.3.0. So my questions are as follows:

1) How to resolve the issue with the two same serial numbers? Is this one or
two disks? Recently one of the disks was broken so SUN technician exchanged
it.

2) Disk 0.10 has a status USED. I assume the status is USED as some previous
filesystem resides on the disk. However, since I want to use it as the global
spare do I have to format it or I can use it as it is and simply initiate:

sccli> configure global-spare 0.10

Thank you in advance, I will summarize.

Kind regards,
Marijan Mumdziev

_______________________________________________

sunmanagers mailing list

sunmanagers@sunmanagers.org

http://www.sunmanagers.org/mailman/listinfo/sunmanagers