Hello,
Many thanks to all who responded to my newbie Sun Ray config question!
-Mike
--------------------------------------------------
Original question (paraphrased):
How can I get older Sun Ray 1 and 150 clients to upgrade their firmware? What
is a dedicated interconnect and how do I set one up?
--------------------------------------------------
Respondents:
- Tim Chipman ( tchipman (-at-) gmail.com )
- Vikash Gupta ( vikashgupta (-at-) yahoo.com )
- Richard Skelton ( Richard.Skelton (-at-) infineon.com )
--------------------------------------------------
Summary:
A dedicated interconnect is a network segment that is not connected
to anything other than the Sun Ray server and Sun Ray clients, and
has no routing other than to the Sun Ray server.
I did wind up uninstalling SRSS and reinstalling it -- until I did
that, no amount of invocation of utadm would get the dedicated
interconnect to work properly. After I reinstalled, all of my clients
were able to get the new firmware and things are working great now.
--------------------------------------------------
Tim Chipman ( tchipman (-at-) gmail.com )
- Dedicated interconnect means a private network structure
- In a configuration where the Sun Ray server has two NICs,
one NIC would need to be connected to a switch or hub that
has no route to the outside world and the only other devices
attached to this network segment are Sun Ray clients
--------------------------------------------------
Vikash Gupta ( vikashgupta (-at-) yahoo.com )
We can setup you existing Sunray Server to act as
Firmware server also.
Please note down your current version of the SunRay
DTU F/W using the (STOP+S) key on DTU.
Required:
1. one dedicated n/w for the firmware server interface
on your U-80 (I am taking hme0)
2. SunRay F/W to be downloaded and put in
/var/tmp/firmware.
Steps:
1. utadm -a hme0 (See below for the detail output)
2. utfwadm -A -
f /var/tmp/firmware/opt/SUNWut/lib/firmware -a -n hme0
3. Connect your SunRay DTU to this hme0 interface thru
a cross cable or some HUB and just power ON,
you will see the SunRay DTU connect to DCHP server
running on U-80 ,do a f/w upgrade and then reboot.
Configuration:
1. utadm -a hme0
### Configuring /etc/nsswitch.conf
### Configuring Service information for Sun Ray
### configuring eth1 interface at subnet 192.168.128.0
Selected values for interface "hme0"
host address: 192.168.128.1
net mask: 255.255.255.0
net address: 192.168.128.0
host name: blrsraysyn01-hme0
net name: SunRay-hme0
first unit address: 192.168.128.16
last unit address: 192.168.128.240
auth server: 192.168.128.1
firmware server: 192.168.128.1
router: 192.168.128.1
alternate servers:
Accept as is? ([Y]/N):
### successfully setup
"/etc/opt/SUNWut/net/hostname.eth1" file
### successfully setup "/etc/hosts" file
### successfully setup "/etc/opt/SUNWut/net/netmasks"
file
### successfully setup "/etc/opt/SUNWut/net/networks"
file
### finished install of "eth1" interface
### Configuring firmware version for Sun Ray
All the units served by "blrsraysyn01" on the
192.168.128.0
network interface, running firmware other than
version
"3.0_51,REV=2004.11.10.16.18" will be upgraded
at their next power-on.
### Configuring Sun Ray Logging Functions
DHCP is not currently running, should I start it?
([Y]/N): Y
[root@blrsraysyn01 firmware]# utfwadm -A -f
/var/tmp/firmware/opt/SUNWut/lib/firmware -a -n eth1
All the units served by "blrsraysyn01" on the
192.168.128.0
network interface, running firmware other than
version
"kent.best31.200503301406" will be upgraded at
their next power-on.
### reinitialized DHCP daemon
--------------------------------------------------
Richard Skelton ( Richard.Skelton (-at-) infineon.com )
Start over:
- remove SRSS
- read chapter 6 of the install guide
- get another switch, plug in the 150s and connect qfe0
of the server to this switch
- install SRSS
- reboot
- read chapter 7 of the install guide
- cd /opt/SUNWut/sbin
- ./utadm -a qfe0
- take all the defaults
- reboot
- turn on the Sun Ray 150s
- they should upgrade the firmware
- the reference guide describes the new icons